Reversible Atrioventricular Block after Electrical Injury / 대한내과학회지
Korean Journal of Medicine
;
: 74-78, 2015.
Artigo
em Coreano
| WPRIM
| ID: wpr-225507
ABSTRACT
Here, we report a case of electrical injury-induced reversible advanced second-degree atrioventricular (AV) block. A 28-year-old male visited the emergency department for palpitations 3 days after receiving an electrical injury from 220 volt alternating current. The initial electrocardiogram (ECG) showed sinus rhythm and first-degree AV block with a prolonged PR interval of 400 ms. There was no structural heart disease or electrolyte imbalance. Follow up ECGs acquired 4-6 days after the electrical injury showed intermittent AV block with a prolonged PR interval of 400-460 ms. Exercise treadmill and atropine provocation tests performed 6 days after electrical injury induced advanced second-degree AV block. His bundle electrogram showed intermittent AH block in a Wenckebach pattern with a prolonged AH interval of 220-360 ms and a normal HV interval. Episodes of AV block decreased remarkably 4 weeks after the electrical injury, and the prolonged PR interval returned to 220 ms after 5 months.
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Assunto principal:
Atropina
/
Seguimentos
/
Técnicas Eletrofisiológicas Cardíacas
/
Eletricidade
/
Eletrocardiografia
/
Serviço Hospitalar de Emergência
/
Bloqueio Atrioventricular
/
Cardiopatias
Tipo de estudo:
Estudo observacional
/
Estudo prognóstico
Limite:
Adulto
/
Humanos
/
Masculino
Idioma:
Coreano
Revista:
Korean Journal of Medicine
Ano de publicação:
2015
Tipo de documento:
Artigo