Your browser doesn't support javascript.
loading
Evaluation on Protrusion of the Imaginary Prostate Volume Using Three-Dimensional Volume Rendering / 의학물리
Article em Ko | WPRIM | ID: wpr-227392
Biblioteca responsável: WPRO
ABSTRACT
This study is to compare the accuracy of evaluation regarding the volume of the prostate, which three-dimensional volume rendering was produced the shape of protrusion, by measuring two kinds of craniocaudal length from the top of the protrusion and from the exclusion of the protrusion as the starting points. For the imaginary protrusion prostate models, total of 10 models were roughly made by using devils-tongue jelly and changing each of the 10 ml of capacity from 10 ml to 100 ml. For the protrusion prostate models aimed at estimating the real volume, through 64 cannel computed tomography (CT) and 3.0 tesla magnetic resonance image (MRI) were conducted by planimetry technique from three-dimensional volume rendering. And then we performed to evaluate on significance of these volumes by wilcoxon signed rank test. Also the obtained volumes data by ellipsoid volume formula were measured the volume of protrusion prostate models two times with each method using the two kinds of craniocaudal length from top of the protrusion and from exclusion of the protrusion as the starting points. Finally, the significance of differences using wilcoxon signed rank test was evaluated between the real volume by planimetry technique and the measured volume by ellipsoid volume formula from three-dimensional volume rendering. The average of the protrusion length on the models was 0.90+/-0.18 mm in CT and was 0.75+/-0.11 mm in MRI. There were not statistically significant difference between MRI and CT from the volume of protrusion prostate models (p=0.414). In MRI (p=0.139) and CT (p=0.057), there were not statistically significant difference between the real volume by planimetry technique and the measured volume by ellipsoid volume from exclusion of the protrusion as the starting points. While, there were statistically significant difference between the real volume by planimetry technique and the measured volume by ellipsoid volume from top of the protrusion as the starting points in MRI (p=0.005) and CT (p=0.005). For the accurate measurement of the protrusion prostate models, the craniocaudal length of the prostate should be measured from the exclusion of the protrusion as the starting points.
Assuntos
Palavras-chave
Texto completo: 1 Índice: WPRIM Assunto principal: Próstata / Espectroscopia de Ressonância Magnética Idioma: Ko Revista: Korean Journal of Medical Physics Ano de publicação: 2009 Tipo de documento: Article
Texto completo: 1 Índice: WPRIM Assunto principal: Próstata / Espectroscopia de Ressonância Magnética Idioma: Ko Revista: Korean Journal of Medical Physics Ano de publicação: 2009 Tipo de documento: Article