Your browser doesn't support javascript.
loading
Evaluation of reverse torque value of abutment screws on CAD/CAM custom-made implant abutments / 대한치과보철학회지
The Journal of Korean Academy of Prosthodontics ; : 128-134, 2012.
Artigo em Coreano | WPRIM | ID: wpr-229219
ABSTRACT

PURPOSE:

The purpose of this study was to compare the screw joint stability between the CADCAM custom-made implant abutment and the prefabricated implant abutment by measuring the reverse torque value after cyclic loading. MATERIALS AND

METHODS:

Twelve screw type implants (Implantium, Dentium Co., Seoul, Korea) were embedded in aluminum cylinder with acrylic resin. The implant specimens were equally divided into 3 groups, and connected to the prefabricated titanium abutments (Implantium, Dentium Co., Seoul, Korea), CADCAM custom-made titanium abutments (Myplant, Raphabio Co., Seoul, Korea) and CADCAM custom-made zirconia abutments (Zirconia Myplant, Raphabio Co., Seoul, Korea). The CAD-CAM milled titanium crown (Raphabio Co., Seoul, Korea) was cemented on each implant abutment by resin cement. Before cyclic loading, each abutment screw was tightened to 30 Ncm and the reverse torque value was measured about 30 minutes later. After the crown specimen was subjected to the sinusoidal cyclic loading (30 to 120 N, 500,000 cycles, 2 Hz), postloading reverse torque value was measured and the reverse torque loss ratio was calculated. Kruskal-Wallis test was used for statistical analysis of the reverse torque loss ratio.

RESULTS:

The CADCAM custom-made titanium abutments presented higher values in reverse torque loss ratio without statistically significant differences than the prefabricated titanium abutments (P>.05). Reverse torque loss ratio of the custom-made zirconia abutments was significantly higher compared to that of the prefabricated titanium abutments (P=.014).

CONCLUSION:

Within the limitation of the present in-vitro study, it was concluded that there was no significant difference in screw joint stability between the CADCAM custom-made titanium abutments and the prefabricated titanium abutments. On the other hand, the CADCAM custom-made zirconia abutments showed lower screw joint stability than prefabricated titanium abutments.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Titânio / Zircônio / Desenho Assistido por Computador / Cimentos de Resina / Torque / Coroas / Alumínio / Mãos / Articulações Idioma: Coreano Revista: The Journal of Korean Academy of Prosthodontics Ano de publicação: 2012 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Titânio / Zircônio / Desenho Assistido por Computador / Cimentos de Resina / Torque / Coroas / Alumínio / Mãos / Articulações Idioma: Coreano Revista: The Journal of Korean Academy of Prosthodontics Ano de publicação: 2012 Tipo de documento: Artigo