Lower capsular contracture of miniprostheses as compared with the conventional silicone implant / 中华整形外科杂志
Chinese Journal of Plastic Surgery
;
(6): 180-182, 2006.
Artigo
em Chinês
| WPRIM
| ID: wpr-240359
ABSTRACT
<p><b>OBJECTIVE</b>To determine if miniprostheses would form a capsule of significantly different biophysical, biochemical and histologic properties than the conventional silicone implant.</p><p><b>METHODS</b>Four miniprostheses (experimental group) and one big silicone implants (control 1 group) were separately implanted beneath the panniculus carnosus muscle of 30 rabbits. After 3 months, measures related to contracture and capsular histology were performed on anesthetized animals.</p><p><b>RESULTS</b>Baker ranking, capsular incision width and capsular thickness of the control groups were evidently higher than that of experimental groups (P < 0.01). Implant compression of the control groups was evidently lower than that of the experimental group. Histology revealed a thinner, more flexed capsule around the miniprostheses as compared with big silicone implants.</p><p><b>CONCLUSIONS</b>The miniprostheses form a looser and thinner capsule than the conventional silicone implant.</p>