Your browser doesn't support javascript.
loading
Study of aniline's penetration capability through rats' complete skin in vitro and normal lab gloves / 中华劳动卫生职业病杂志
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 683-685, 2012.
Artigo em Chinês | WPRIM | ID: wpr-242762
ABSTRACT
<p><b>OBJECTIVE</b>To study the permeability of intact mouse abdominal skin to aniline and the protective capability of two typical lab gloves against aniline.</p><p><b>METHODS</b>A Franz diffusion cell was used to perform in vitro transdermal absorption test and glove permeation test for aniline (0.102 mg/ml and 0.010 mg/ml). The permeabilities of intact mouse abdominal skin and gloves to aniline were measured by high performance liquid chromatography-diode array detection.</p><p><b>RESULTS</b>The transdermal penetration of the two concentrations of aniline followed zero order kinetics within 12 h, exhibiting total aniline permeabilities within 24 h of 51.71% and 48.31%, respectively. The absorption liquid had an aniline concentration of at least 18 µg/L. The medical disposable latex glove could not stop the penetration of 0.010 mg/ml aniline, but the industrial natural latex glove could.</p><p><b>CONCLUSION</b>The penetration of 0.102 mg/ml and 0.010 mg/ml aniline through the mouse abdominal skin follows zero order kinetics within 12 h. The medical disposable latex glove cannot stop the penetration of 0.010 mg/ml aniline, but the industrial natural latex glove can.</p>
Assuntos
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Absorção Cutânea / Farmacocinética / Luvas Protetoras / Toxicidade / Compostos de Anilina Limite: Animais Idioma: Chinês Revista: Chinese Journal of Industrial Hygiene and Occupational Diseases Ano de publicação: 2012 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Absorção Cutânea / Farmacocinética / Luvas Protetoras / Toxicidade / Compostos de Anilina Limite: Animais Idioma: Chinês Revista: Chinese Journal of Industrial Hygiene and Occupational Diseases Ano de publicação: 2012 Tipo de documento: Artigo