Your browser doesn't support javascript.
loading
An in vitro study of retentive force and deformation of resin clasp / 华西口腔医学杂志
West China Journal of Stomatology ; (6): 422-429, 2009.
Artigo em Chinês | WPRIM | ID: wpr-242988
ABSTRACT
<p><b>OBJECTIVE</b>To study the retentive force and deformation of acetal resin clasp.</p><p><b>METHODS</b>40 premolars and 40 molars were cast respectively. Undercut of 0.25 mm or 0.50 mm depth were measured for each with undercut gage. According to the type of abutment and the depth of undercut, the specimens were divided into 4 groups Premolars with 0.25 mm undercut, premolars with 0.50 mm undercut, molars with 0.25 mm undercut and molars with 0.50 mm undercut, 20 specimens each group. 10 three-arm clasps with resin and Co-Cr alloy were fabricated in each group, respectively. The clasps were set into the corresponding abutments and soaked in distilled water. The retentive force of the clasps when 0, 720, 1440, 2160, 2880, 3600, 4320 consecutive times of setting in and removing out from the abutments were measured. The distance between the tips of retentive arm and resistant arm after 0 and 4320 cycles were recorded.</p><p><b>RESULTS</b>1) The mean retentive force of resin clasps (1.69 N) was significantly lower than that of Co-Cr clasps (5.87 N) (P<0.01). With the same factors, the retentive force of resin clasps were significantly less than that of Co-Cr clasps (P<0.01). The retentive force of molar clasps were significantly lower than that of premolar models (P<0.01). The retentive force of 0.25 mm undercut clasps were significantly lower than that of 0.50 mm undercut clasps (P<0.01). With increasing time of the cycles, the retentive force of Co-Cr clasps significantly reduced (P<0.01), but the retentive force of resin clasps didn't change significantly (P>0.05). 2) After 4320 times, the distance between the tips of retentive arm and resistant arm of Co-Cr clasps increased significantly (P<0.05), but the distance between the tips of resin clasps didn't change significantly (P>0.05).</p><p><b>CONCLUSION</b>The retentive force and deformation of the resin clasp are significantly lower than those of Co-Cr clasp.</p>
Assuntos
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Dente Pré-Molar / Técnicas In Vitro / Ligas de Cromo / Retenção de Dentadura / Grampos Dentários Tipo de estudo: Estudo prognóstico Limite: Humanos Idioma: Chinês Revista: West China Journal of Stomatology Ano de publicação: 2009 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Dente Pré-Molar / Técnicas In Vitro / Ligas de Cromo / Retenção de Dentadura / Grampos Dentários Tipo de estudo: Estudo prognóstico Limite: Humanos Idioma: Chinês Revista: West China Journal of Stomatology Ano de publicação: 2009 Tipo de documento: Artigo