Application of intraoperative arterial pressure-based cardiac output monitoring for patients undergoing coronary artery bypass grafting surgery / 中华医学杂志(英文版)
Chin. med. j
; Chin. med. j;(24): 2099-2103, 2012.
Article
em En
| WPRIM
| ID: wpr-244405
Biblioteca responsável:
WPRO
ABSTRACT
<p><b>BACKGROUND</b>For patients undergoing off-pump coronary artery bypass grafting (OPCABG), it is important to establish a hemodynamic monitoring system to obtain powerful parameters for better intraoperative treatment. This study aimed to observe the clinical feasibility of arterial pressure-based cardiac output (APCO) for cardiac output (CO) monitoring and to evaluate the correlation between APCO and pulmonary artery catheter (PAC) for CO measurement for patients undergoing OPCABG intraoperatively.</p><p><b>METHODS</b>Fifty patients of American Society of Anaesthesiologists (ASA) classification II-III, undergoing elective OPCABG at Beijing Anzhen Hospital were randomly enrolled into this study. All patients were assigned to CO monitoring by PAC and APCO simultaneously. Patients with pacemaker, severe valvular heart disease, left ventricular ejection fraction (EF) < 40%, cardiac arrhythmias, peripheral vascular disease, application of intra-aortic balloon pump (IABP) and emergent diversion to cardiac pulmonary bypass were excluded. The radial artery waveform was analyzed to estimate the stroke volume (SV) and heart rate (HR) continuously. CO was calculated as SV ' HR; other derived parameters were cardiac index (CI), stroke volume index (SVI), systemic vascular resistance (SVR), and systemic vascular resistance index (SVRI). PAC was placed via right internal jugular vein and the correct position was confirmed by PAC waveforms. Continuous cardiac output (CCO), CI and other hemodynamic parameters were monitored at following 5 time points: immediate after anesthesia induction (baseline value), anastomosis of left internal mammary artery to left anterior descending artery (LAD), anastomosis of left circumflex (LCX), anastomosis of posterior descending artery (PDA) and immediate after sternal closure.</p><p><b>RESULTS</b>In the 50 patients, preoperative echocardiography measured left ventricular EF was (52.8 ± 11.5)%, and 35 patients (70%) showed regional wall motion abnormalities. The correlation coefficient of CO monitored by APCO and PAC were 0.70, 0.59, 0.78, 0.74 and 0.85 at each time point. The bias range of CI monitored from both APCO and PAC were (0.39 ± 0.06) L×min(-1)×m(-2), (0.48 ± 0.12) L×min(-1)×m(-2), (0.26 ± 0.06) L×min(-1)×m(-2), (0.27 ± 0.06) L×min(-1)×m(-2), (0.30 ± 0.05) L×min(-1)×m(-2) at each time point. The results of SVR by two hemodynamic monitoring techniques had good correlation during OPCABG. The variation trends of SVR were opposite comparing with the results of CO. SVR collected from PAC obtained the highest value of (1220.0 ± 254.0) dyn×s×cm(-5) at PDA anastomosis, but the highest value obtained from APCO was (1206.0 ± 226.5) dyn×s×cm(-5) in LCX anastomosis.</p><p><b>CONCLUSIONS</b>APCO is feasible in hemodynamic monitoring for patients undergoing OPCABG. The results of hemodynamic monitoring derived from APCO and PAC are closely correlated. Its characterizations of timely, accurate and continuous display of hemodynamic parameters are also obviously demonstrated in the present study.</p>
Texto completo:
1
Índice:
WPRIM
Assunto principal:
Fisiologia
/
Cateterismo de Swan-Ganz
/
Débito Cardíaco
/
Ponte de Artéria Coronária
/
Monitorização Intraoperatória
/
Pressão Arterial
/
Hemodinâmica
/
Métodos
Limite:
Aged
/
Female
/
Humans
/
Male
Idioma:
En
Revista:
Chin. med. j
Ano de publicação:
2012
Tipo de documento:
Article