Your browser doesn't support javascript.
loading
Early experiences with robot-assisted total knee arthroplasty using the DigiMatch™ ROBODOC® surgical system
Singapore medical journal ; : 529-534, 2014.
Artigo em Inglês | WPRIM | ID: wpr-244755
ABSTRACT
<p><b>INTRODUCTION</b>The use of robotics in total knee arthroplasty (TKA) has been shown to minimise human error, as well as improve the accuracy and precision of component implantation and mechanical axis alignment. The present study aimed to demonstrate that robot-assisted TKA using ROBODOC® is safe and capable of producing a consistent and accurate postoperative mechanical axis.</p><p><b>METHODS</b>We prospectively recruited 27 consecutive patients who underwent robot-assisted TKA between May and December 2012. Two patients were excluded from the study due to intraoperative technical problems with the robot. Long-leg radiography and computed tomography were performed prior to surgery, and used for mechanical axis measurements and component sizing. DigiMatch™ ROBODOC® Surgical System software version 4.3.6 (Curexo Technology Corp, Fremont, CA, USA) was used in all cases to perform bone cuts in accordance with the preoperative plan.</p><p><b>RESULTS</b>The postoperative coronal mechanical alignment was within 3 degrees, with a mean alignment of -0.4 ± 1.7 degrees, confirming the accuracy of the preoperative surgical plan and bone cuts. The mean operating time was 96 ± 15 min, and preoperative planning yielded 100% implant sizing accuracy.</p><p><b>CONCLUSION</b>Robotics has the potential to enable surgeons to consistently attain ideal postoperative alignment. The use of bone movement monitors and an integrated navigation system enhances the safety profile of ROBODOC® by minimising errors. However, the role of the surgeon in TKA is still vital, as the surgeon is ultimately in charge of planning the surgery, its execution and ensuring soft tissue balance during TKA.</p>
Assuntos
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Cirurgia Geral / Tíbia / Diagnóstico por Imagem / Tomografia Computadorizada por Raios X / Estudos Prospectivos / Artroplastia do Joelho / Procedimentos Cirúrgicos Robóticos / Articulação do Joelho Tipo de estudo: Estudo diagnóstico / Estudo observacional Limite: Idoso / Feminino / Humanos / Masculino Idioma: Inglês Revista: Singapore medical journal Ano de publicação: 2014 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Cirurgia Geral / Tíbia / Diagnóstico por Imagem / Tomografia Computadorizada por Raios X / Estudos Prospectivos / Artroplastia do Joelho / Procedimentos Cirúrgicos Robóticos / Articulação do Joelho Tipo de estudo: Estudo diagnóstico / Estudo observacional Limite: Idoso / Feminino / Humanos / Masculino Idioma: Inglês Revista: Singapore medical journal Ano de publicação: 2014 Tipo de documento: Artigo