Study on the effect of bone-cement interface with bone cement oscillator / 中华外科杂志
Chinese Journal of Surgery
; (12): 431-433, 2008.
Article
em Zh
| WPRIM
| ID: wpr-245563
Biblioteca responsável:
WPRO
ABSTRACT
<p><b>OBJECTIVE</b>To evaluate the effect on increasing bone cement-bone interface micro-gomphosis intensity with bone cement oscillator.</p><p><b>METHODS</b>One hundred femoral bones of adult pig were randomly divided into 6 groups: oscillating group (A1) and control group (A2) of anti-tensile force, oscillating group (B1) and control group (B2) of anti-pressure (n = 20 in each group), oscillating group (C1) and control group (C2) of imaging (n = 10 in each group). Mechanics and CT test was performed, micro-gomphosis intensity of bone cement-bone interface between oscillating group and control group was compared.</p><p><b>RESULTS</b>Mechanics and CT test showed bone cement-bone interface micro-gomphosis intensity in oscillating group was significantly stronger than control group (P < 0.01).</p><p><b>CONCLUSION</b>Bone cement oscillator can significantly increase micro-gomphosis intensity of bone-cement interface, and reduce long-term aseptic loosening of artificial prostheses.</p>
Texto completo:
1
Índice:
WPRIM
Assunto principal:
Suínos
/
Vibração
/
Cimentos Ósseos
/
Teste de Materiais
/
Distribuição Aleatória
/
Cimentação
/
Mecânica
/
Desenho de Equipamento
/
Fêmur
/
Prótese Articular
Limite:
Animals
Idioma:
Zh
Revista:
Chinese Journal of Surgery
Ano de publicação:
2008
Tipo de documento:
Article