Your browser doesn't support javascript.
loading
External quality assessment on detection of hepatitis C virus RNA in clinical laboratories of China / 中华医学杂志(英文版)
Chinese Medical Journal ; (24): 1032-1036, 2008.
Artigo em Inglês | WPRIM | ID: wpr-258520
ABSTRACT
<p><b>BACKGROUND</b>As with many studies carried out in European countries, a quality assurance program has been established by the National Center for Clinical Laboratories in China (NCCL). The results showed that the external quality assessment significantly improves laboratory performance for quantitative evaluation of hepatitis C virus (HCV) RNA.</p><p><b>METHODS</b>Serum panels were delivered twice annually to the clinical laboratories which performed HCV RNA detection in China. Each panel made up of 5 coded samples. All laboratories were requested to carry out the detection within the required time period and report on testing results which contained qualitative and/or quantitative test findings, reagents used and relevant information about apparatus. All the positive samples were calibrated against the first International Standard for HCV RNA in a collaborative study and the range of comparison target value (TG) designated as +/- 0.5 log.</p><p><b>RESULTS</b>The numbers of laboratories reporting on qualitative testing results for the first and second time external quality assessment were 168 and 167 in the year of 2003 and increased to 209 and 233 in 2007; the numbers of laboratories reporting on quantitative testing results were 134 and 147 in 2003 and rose to 340 and 339 in 2007. Deviation between the mean value for quantitative results at home in 2003 and the target value was above 0.5 log, which was comparatively high. By 2007, the target value was close to the national average except for the low concentrated specimens (10(3) IU/ml). The percentage of results within the range of GM +/- 0.5 log(10) varied from 8.2% to 93.5%. Some laboratories had some difficulties in the exact quantification of the lowest (3.00 log IU/ml) as well as of the highest viral levels (6.37 log IU/ml) values, very near to the limits of the dynamic range of the assays.</p><p><b>CONCLUSIONS</b>The comparison of these results with the previous study confirms that a regular participation in external quality assessment (EQA) assures the achievement of a high proficiency level in the diagnosis of HCV infection. During the 5-year external quality assessment, sensitivity and accuracy of detection in most of the clinical laboratories have been evidently improved and the quality of kits has also been substantially improved.</p>
Assuntos
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Controle de Qualidade / Kit de Reagentes para Diagnóstico / Padrões de Referência / RNA Viral / Reação em Cadeia da Polimerase / Hepacivirus / Genética / Laboratórios Tipo de estudo: Estudo diagnóstico / Pesquisa qualitativa Limite: Humanos Idioma: Inglês Revista: Chinese Medical Journal Ano de publicação: 2008 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Controle de Qualidade / Kit de Reagentes para Diagnóstico / Padrões de Referência / RNA Viral / Reação em Cadeia da Polimerase / Hepacivirus / Genética / Laboratórios Tipo de estudo: Estudo diagnóstico / Pesquisa qualitativa Limite: Humanos Idioma: Inglês Revista: Chinese Medical Journal Ano de publicação: 2008 Tipo de documento: Artigo