Your browser doesn't support javascript.
loading
Changes in mechanical properties of seven light-cured composite resins after thermal cycling / 南方医科大学学报
Journal of Southern Medical University ; (12): 1957-1962, 2011.
Artigo em Inglês | WPRIM | ID: wpr-265740
ABSTRACT
<p><b>OBJECTIVE</b>To examine the changes of the mechanical properties of 7 different light-cured composite resins after thermal cycling and the correlations between these properties.</p><p><b>METHODS</b>Seven different light-cured composite resins, including 2 microfilled composites (A110AH and ESTELITEET), 3 microhybrid composites (AELITEAT, Z250ZS, and CharmFil plusCP), and 2 nanohybrid composites (Z350ZH and GrandioGD), were prepared into test specimens with a diameter of 12 mm and a thickness of 1.0 mm. The specimens were stored in distilled water at 37 degrees celsius; for 24 h prior to 1 000 thermal cycles of 5 degrees celsius; for 15 s and 55 degrees celsius; for 15 s. The biaxial flexural strength (&delta;(f)) was tested using the ball-on-three-ball method at a crosshead speed of 0.5 mm/min (ISO4049). The fracture surface was observed under scanning electron microscope (SEM), and the remaining specimens underwent Knoop hardness test with a 50-g loading for 10 s.</p><p><b>RESULTS</b>The highest and lowest Weibull modulus was observed in AH (18.752) and AT (5.290) group, respectively. The highest and lowest biaxial flexural strength was observed in ZS (158.2 MPa) and ET (54.0 MPa) groups, respectively. The &delta;(f) of the tested materials decreased in the order of microhybrid composite, nanohybrid composite, and microfiller composite, and the &delta;(f) showed no significant difference between the composites with a similar filler (P>0.05). The fracture number was positively correlated to the strength of the material. The Knoop hardness numbers (H) was the highest in GD group (110.81∓14.77 kg/mm(2)) and the lowest in AH group (42.81∓1.91 kg/mm(2)). SEM showed that the interface region of the matrix and the filler was vulnerable to crack formation.</p><p><b>CONCLUSION</b>The nanohybrid composite resins better suit clinical applications than microhybrid composites. The applicability of Knoop hardness test in hardness measurement of the composite resins needs to be further demonstrated.</p>
Assuntos
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Estresse Mecânico / Temperatura / Resistência à Tração / Teste de Materiais / Química / Resinas Compostas / Nanocompostos / Nanopartículas Idioma: Inglês Revista: Journal of Southern Medical University Ano de publicação: 2011 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Estresse Mecânico / Temperatura / Resistência à Tração / Teste de Materiais / Química / Resinas Compostas / Nanocompostos / Nanopartículas Idioma: Inglês Revista: Journal of Southern Medical University Ano de publicação: 2011 Tipo de documento: Artigo