Effect of plasmaslyte A on the liver function of patients undergoing cardiac surgery with extracorporeal circulation / 南方医科大学学报
Journal of Southern Medical University
; (12): 2588-2589, 2010.
Article
em Zh
| WPRIM
| ID: wpr-267729
Biblioteca responsável:
WPRO
ABSTRACT
<p><b>OBJECTIVE</b>To observe the effect of plasmaslyte A on the liver function of patients receiving cardiac surgery with extracorporeal circulation.</p><p><b>METHODS</b>Sixty patients scheduled for cardiac surgery were randomized to receive plasmaslyte A (group P, n=30) and ringer lactate solution (group R, n=30). The two agents were used in priming heart-lung machine and intra- and postoperative crystal solution. All the patients were examined for the levels of AST, ALT and Lac the day before and at 2 h and 1, 3 and 7 days after the surgery. The time of extubation and length of stay at the ICU were record.</p><p><b>RESULTS</b>The levels of ALT, AST and Lac in group P were significantly lower than those in group R (P<0.05), and the duration of intubation and stay at the ICU was shorter in group P (P<0.05).</p><p><b>CONCLUSION</b>Plasmaslyte A can markedly reduce the level of AST, ALT and Lac and protect the liver function of patients undergoing cardiac surgery with extracorporeal circulation.</p>
Texto completo:
1
Índice:
WPRIM
Assunto principal:
Farmacologia
/
Circulação Extracorpórea
/
Procedimentos Cirúrgicos Cardíacos
/
Soluções Isotônicas
/
Testes de Função Hepática
Tipo de estudo:
Clinical_trials
Limite:
Adult
/
Aged
/
Female
/
Humans
/
Male
Idioma:
Zh
Revista:
Journal of Southern Medical University
Ano de publicação:
2010
Tipo de documento:
Article