Your browser doesn't support javascript.
loading
Influence of the insert design on clinical results and kinematics of the knee after total knee arthroplasty / 中华外科杂志
Chinese Journal of Surgery ; (12): 1556-1560, 2010.
Artigo em Chinês | WPRIM | ID: wpr-270918
ABSTRACT
<p><b>OBJECTIVE</b>To investigate the influence of the insert design of knee prosthesis on clinical results and kinematics of the knee after total knee arthroplasty (TKA).</p><p><b>METHODS</b>Forty-two knees in 28 patients with knee osteoarthritis undergoing TKA using the GENESIS II from July 2007 to June 2009 were included in this study, mean follow-up of 27.7 months. The cases were divided into 2 groups according to the type of insert, one was high flexion insert group (23 knees) and the other was standard insert group (19 knees). Two groups were compared by clinical ratings of knee function. The motion of flexion and extension of the two groups was observed by cyclic fluoroscopy and the data was analyzed by mapping software. The influence of the insert design of knee prosthesis on kinematics of the knee after TKA was investigated by comparing the parameters of the two groups during the movement of knee joint, including femoral roll back and extensor mechanism arm.</p><p><b>RESULTS</b>The range of motion of standard insert group and high flexion insert group was 120° and 123° respectively with no difference between them. There was no difference of knee society clinical rating system in both groups. Feller score of high flexion insert group was higher than the standard insert group, the difference was significant statistically (P = 0.012). In the imaging measurement, the two groups had no differences in femoral rollback and extensor mechanism arm during the 0 to 120° range of movement. The two groups appeared significant statistically (P = 0.034) in the extensor mechanism arm when flexion extended to 130°.</p><p><b>CONCLUSIONS</b>The high flexion improved design may play a certain role on reducing anterior knee pain and improving knee function after TKA. However, the improved design may be reduced the extensor mechanism arm when high flexion, so that affecting the work ability of quadriceps.</p>
Assuntos
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Período Pós-Operatório / Desenho de Prótese / Seguimentos / Resultado do Tratamento / Artroplastia do Joelho / Articulação do Joelho / Prótese do Joelho Tipo de estudo: Estudo observacional / Estudo prognóstico Limite: Idoso / Feminino / Humanos / Masculino Idioma: Chinês Revista: Chinese Journal of Surgery Ano de publicação: 2010 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Período Pós-Operatório / Desenho de Prótese / Seguimentos / Resultado do Tratamento / Artroplastia do Joelho / Articulação do Joelho / Prótese do Joelho Tipo de estudo: Estudo observacional / Estudo prognóstico Limite: Idoso / Feminino / Humanos / Masculino Idioma: Chinês Revista: Chinese Journal of Surgery Ano de publicação: 2010 Tipo de documento: Artigo