Your browser doesn't support javascript.
loading
Amino-terminal pro-brain natriuretic peptide and brain natriuretic peptide measurements under various detection conditions in patients with chronic heart failure / 中华心血管病杂志
Chinese Journal of Cardiology ; (12): 695-699, 2011.
Artigo em Chinês | WPRIM | ID: wpr-272177
ABSTRACT
<p><b>OBJECTIVE</b>To find the potential interference factors for the detection of NT-proBNP and BNP in patients with chronic heart failure.</p><p><b>METHODS</b>EP15-A2 issued by Clinical and Laboratory Standards Institute (CLSI) was employed to compare the precision and accuracy of commercial NT-proBNP and BNP analyzer electrochemiluminescence immunoassay system Cobas E601 and chemiluminescence system ADVIA Centaur. Moreover, NT-proBNP and BNP were detected in different time interval and in different interfered sampling conditions (haematolysis, choloplania, lipemia). NT-proBNP and BNP of 203 patients with heart failure or heart failure complicated with acute cerebral infarction were analyzed to find the deviation caused by patients' endogenous factors.</p><p><b>RESULTS</b>The precision and accuracy were comparable for NT-proBNP and BNP detection using Cobas E601 and ADVIA Centaur (total-CV below 2.9% and 3.5%, the deviation from definite value below 2.38% and 3.91%). The most suitable sample type for NT-proBNP and BNP detection was serum and EDTA-anticoagulant plasma. The detection results of NT-proBNP and BNP were comparable for at least 120 min post sampling and not affected by Hb (2 g/L), DB (428 µmol/L) and chyle (2000 FIU). NT-proBNP was significantly higher in heart failure patients complicated with cerebral infarction (P = 0.003) than in heart failure patients. BNP was significantly higher in heart failure grade III patients complicated with cerebral infarction (P < 0.01).</p><p><b>CONCLUSIONS</b>Cobas E601 and ADVIA Centaur supplied satisfactory detection of NT-proBNP and BNP in patients with chronic heart failure with strong anti-interference capacity. The diagnostic value of NT-proBNP and BNP for chronic heart failure should be analyzed objectively in the presence of complicating diseases.</p>
Assuntos
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Fragmentos de Peptídeos / Padrões de Referência / Manejo de Espécimes / Sangue / Imunoensaio / Sensibilidade e Especificidade / Peptídeo Natriurético Encefálico / Diagnóstico / Técnicas Eletroquímicas / Insuficiência Cardíaca Tipo de estudo: Estudo diagnóstico / Guia de Prática Clínica Limite: Humanos Idioma: Chinês Revista: Chinese Journal of Cardiology Ano de publicação: 2011 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Fragmentos de Peptídeos / Padrões de Referência / Manejo de Espécimes / Sangue / Imunoensaio / Sensibilidade e Especificidade / Peptídeo Natriurético Encefálico / Diagnóstico / Técnicas Eletroquímicas / Insuficiência Cardíaca Tipo de estudo: Estudo diagnóstico / Guia de Prática Clínica Limite: Humanos Idioma: Chinês Revista: Chinese Journal of Cardiology Ano de publicação: 2011 Tipo de documento: Artigo