Your browser doesn't support javascript.
loading
Comparison between Doppler echocardiography and hot-film anemometry in measuring the turbulent shear stress downstream of artificial mitral valves: a methodological study / 中华医学杂志(英文版)
Chinese Medical Journal ; (24): 2174-2178, 2013.
Artigo em Inglês | WPRIM | ID: wpr-273016
ABSTRACT
<p><b>BACKGROUND</b>Turbulent shear stress (TSS) plays an important role in the research of fluid dynamics of heart valves. This study aimed to perform a quantitative study of TSS downstream of porcine artificial mitral valves in order to verify the correlation of hot-film anemometry (HFA) and Doppler echocardiography combined with computer-aided image analysis for the detection of TSS.</p><p><b>METHODS</b>A porcine model of mitral valve replacement was established. HFA and Doppler ultrasound techniques were used to directly and indirectly measure TSS-relevant parameters of the artificial mitral valve following different mitral valve replacements different approaches were used to reserve the subvalvular apparatus of the mitral valve. A correlation analysis was then carried out.</p><p><b>RESULTS</b>There was a significant correlation between the HFA and Doppler ultrasound combined with computer-aided image analysis of the TSS at the same time and at the same site. No significant difference was found in the TSS measured by the two methods.</p><p><b>CONCLUSIONS</b>Compared with HFA, Doppler echocardiography combined with computer-aided image analysis is a safe, non-invasive, and real-time method that enables accurate and quantitative detection of TSS downstream in vivo, objectively reflecting the flow field downstream of the artificial mitral valve. Doppler ultrasound combined with computer-aided image analysis can be employed for quantitatively evaluating the downstream hemodynamic performance of the mitral valve.</p>
Assuntos
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Reologia / Estresse Mecânico / Cirurgia Geral / Suínos / Processamento de Imagem Assistida por Computador / Fluxo Pulsátil / Próteses Valvulares Cardíacas / Diagnóstico por Imagem / Ecocardiografia Doppler / Métodos Tipo de estudo: Estudo diagnóstico Limite: Animais Idioma: Inglês Revista: Chinese Medical Journal Ano de publicação: 2013 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Reologia / Estresse Mecânico / Cirurgia Geral / Suínos / Processamento de Imagem Assistida por Computador / Fluxo Pulsátil / Próteses Valvulares Cardíacas / Diagnóstico por Imagem / Ecocardiografia Doppler / Métodos Tipo de estudo: Estudo diagnóstico Limite: Animais Idioma: Inglês Revista: Chinese Medical Journal Ano de publicação: 2013 Tipo de documento: Artigo