Your browser doesn't support javascript.
loading
Effect of tube voltage on digital chest radiograph for phantom and occupational exposed workers / 中华劳动卫生职业病杂志
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 671-674, 2013.
Artigo em Chinês | WPRIM | ID: wpr-275859
ABSTRACT
<p><b>OBJECTIVE</b>To explore the image quality of different tube voltage on digital chest radiograph for contrast detail phantom (CDRAD2.0) and occupational exposed workers.</p><p><b>METHODS</b>The CDRAD2.0 phantom DR images of high KV and different tube voltages were analyzed by 3 readers, image quality figure (IQF) were calculated and compared; at the same time 136 exposed workers were examined with high-kV and DR chest radiograph of different tube voltages. Contrast to high-KV images, 10 anatomic sites were scored .The image differences were compared between DR and high-kV.</p><p><b>RESULTS</b>On CDRAD2.0 phantom, the IQF value of DR images in 3 readers were minimum in the condition of 120 kV, average value was 22.25. The analysis of variance in model with random effects, the mean IQF value of different tube voltage DR image had a significant difference (F = 13.775, P<0.01); By Dunnett t-tests analysis, the mean IQF value of DR image in 120 kV and high kilovoltage had no difference (t = -0.58, P = 0.979); On clinical cases, the DR image of 120 kV showed the closest anatomy to the high KV, the mean had no significant difference with 0 (P > 0.05) with single sample t test.</p><p><b>CONCLUSION</b>On the CDRAD2.0 phantom or clinical exposed workers, the DR image quality of 120 kV tube voltage equals to high-KV basically.</p>
Assuntos
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Radiografia Torácica / Intensificação de Imagem Radiográfica / Exposição Ocupacional / Poeira / Métodos Tipo de estudo: Estudo prognóstico Limite: Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Chinês Revista: Chinese Journal of Industrial Hygiene and Occupational Diseases Ano de publicação: 2013 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Radiografia Torácica / Intensificação de Imagem Radiográfica / Exposição Ocupacional / Poeira / Métodos Tipo de estudo: Estudo prognóstico Limite: Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Chinês Revista: Chinese Journal of Industrial Hygiene and Occupational Diseases Ano de publicação: 2013 Tipo de documento: Artigo