Your browser doesn't support javascript.
loading
Comparison of Non-invasive Imaging Studies in the Evaluation of Carotid Artery Stenosis and Occlusion: CT Angiography, Time-of-Flight MR Angiography and Contrast-Enhanced MR Angiography
Article em Ko | WPRIM | ID: wpr-27666
Biblioteca responsável: WPRO
ABSTRACT
PURPOSE: We compared non-invasive imaging studies of CTA, TOF-MRA and CE-MRA to evaluate detecting internal carotid artery stenosis and occlusion. MATERIALS AND METHODS: We enrolled 20 patients with clinically suspected internal carotid artery stenosis and occlusion, or asymptomatic patient with more than 50% stenosis suspected on color Doppler ultrasonography for regular check-up. Prospectively, CTA, TOF-MRA and CE-MRA were performed, and sensitivity, specificity, positive predictive value, negative predictive value and accuracy of TOF-MRA and CE-MRA using CTA as a reference standard for detecting more than 50% stenosis were evaluated, and correlations of measured percent stenosis between 3 imaging studies were also evaluated. RESULTS: No significant difference was found between 3 imaging studies in measuring stenosis(p>0.05). Correlation coefficient was 0.932 between CTA and TOF-MRA, and 0.971 between CTA and CE-MRA. TOF-MRA had 83.3% sensitivity, 87.5% specificity, 71.4% positive predictive value, 93.3% negative predictive value and 86.4% accuracy for detecting more than 50% stenosis and occlusion. CE-MRA had 83.3% sensitivity, 93.8% specificity, 83.3% positive predictive value, 93.8% negative predictive value and 90.9% accuracy. CONCLUSION: TOF-MRA and CE-MRA provided high correlations in the evaluation of internal carotid artery stenosis and occlusion.
Assuntos
Palavras-chave
Texto completo: 1 Índice: WPRIM Assunto principal: Angiografia / Artérias Carótidas / Estudos Prospectivos / Sensibilidade e Especificidade / Estenose das Carótidas / Ultrassonografia Doppler em Cores / Constrição Patológica Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Humans Idioma: Ko Revista: Journal of the Korean Society of Magnetic Resonance in Medicine Ano de publicação: 2011 Tipo de documento: Article
Texto completo: 1 Índice: WPRIM Assunto principal: Angiografia / Artérias Carótidas / Estudos Prospectivos / Sensibilidade e Especificidade / Estenose das Carótidas / Ultrassonografia Doppler em Cores / Constrição Patológica Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Humans Idioma: Ko Revista: Journal of the Korean Society of Magnetic Resonance in Medicine Ano de publicação: 2011 Tipo de documento: Article