Application of multi-slice spiral CT angiography after endoluminal exclusion of aortic diseases / 中国医学科学院学报
Acta Academiae Medicinae Sinicae
;
(6): 93-95, 2006.
Artigo
em Chinês
| WPRIM
| ID: wpr-281254
ABSTRACT
<p><b>OBJECTIVE</b>To study the application of multi-slice spiral CT angiography (MSCTA) after endoluminal exclusion of aortic diseases.</p><p><b>METHODS</b>16-slice CT angiography was performed in 15 patients with aortic dissection and 4 patients with aortic aneurysm after endovascular exclusion. Two observers analysed the images and interpreted the outcomes and complications after endovascular exclusions of aortic dissection and aortic aneurysm.</p><p><b>RESULTS</b>In 19 patients, thrombus was found in all the false lumens of aortic dissection and the outer-stent cavity of aortic aneurysm. However, one patient with aortic aneurysm graft thrombosis; 4 patients had endo-leak (3 with type I endo-leak, 1 with type III endo-leak complicating graft deformation); one achieved perfusion recovery, and one experienced thrombolysis of superior mesenteric artery.</p><p><b>CONCLUSION</b>MSCTA can be an objective tool for the post-operative evaluation of endovascular exclusion of aortic diseases.</p>
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Assunto principal:
Período Pós-Operatório
/
Cirurgia Geral
/
Diagnóstico por Imagem
/
Angiografia
/
Aneurisma da Aorta Abdominal
/
Tomografia Computadorizada Espiral
/
Dissecção Aórtica
/
Métodos
Tipo de estudo:
Estudo diagnóstico
Limite:
Adulto
/
Idoso
/
Feminino
/
Humanos
/
Masculino
Idioma:
Chinês
Revista:
Acta Academiae Medicinae Sinicae
Ano de publicação:
2006
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS