Your browser doesn't support javascript.
loading
Localization and distribution of magnetic chemotherapeutic drugs with magnetic targeting in rat brain / 中华医学杂志(英文版)
Chinese Medical Journal ; (24): 824-827, 2005.
Artigo em Inglês | WPRIM | ID: wpr-288293
ABSTRACT
<p><b>BACKGROUND</b>Magnetic targeting therapy may be a new method for the treatment of malignent tumors. The purpose of this study was to investigate the localization and distribution of ferrofluid microsphere of human serum albumin methotrexate (FM-HSA-MTX) carriers in the brain and to explore the magnetic targeting chemotherapy for malignant brain tumor.</p><p><b>METHODS</b>Ninety SD rats were divided into three groups targeting group, non-magnetic targeting group, and control group. Synthesized FM-HSA-MTX carriers (MTX 25 mg/kg) were injected into the systemic circulation via the caudal vein (magnetic targeting group, n = 30). A 0.6 T magnetic field was placed around the right hemisphere. The non-magnetic targeting group (n = 30) was administered with FM-HSA-MTX without external magnetic field, meanwhile the control group (n = 30) was treated with MTX and a magnetic field. Random serial sacrifices (n = 10) were conducted at 15, 30 and 45 minutes after drug administration. Bilateral hemispheres were collected respectively, and analyzed for total MTX content.</p><p><b>RESULTS</b>MTX content in the right hemisphere of the magnetic targeting group was significantly higher than that in the other two groups at 15, 30 and 45 minutes after drug administration (P < 0.05) No difference was seen between the non-targeting group and control group. In the magnetic targeting group, MTX returned to the peak level [(0.564 +/- 0.018) mg/g, q15-45 = 32.252, P < 0.05] 45 minutes after the injection but it deceased in the other two groups [non-magnetic targeting group (0.060 +/- 0.015) mg/g, q15-45 = 9.245, P < 0.05, control group (0.074 +/- 0.045) mg/g, q15-45 = 6.299, P < 0.05]. In the magnetic targeting group, the concentration of MTX in the right hemisphere was significantly higher than that in the left hemisphere (t45min = 21.135, P = 0.000) but no difference was observed between bilateral hemispheres in the other two groups (non-magnetic targeting group t45min = 0.434, P = 0.670; control group t45min = 0.533, P = 0.600).</p><p><b>CONCLUSION</b>In the presence of the external magnetic field, FM-HSA-MTX can distribute successfully in the targeting areas of the brain.</p>
Assuntos
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Encéfalo / Albumina Sérica / Portadores de Fármacos / Farmacocinética / Metotrexato / Ratos Sprague-Dawley / Magnetismo / Metabolismo / Microesferas / Antineoplásicos Limite: Animais Idioma: Inglês Revista: Chinese Medical Journal Ano de publicação: 2005 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Encéfalo / Albumina Sérica / Portadores de Fármacos / Farmacocinética / Metotrexato / Ratos Sprague-Dawley / Magnetismo / Metabolismo / Microesferas / Antineoplásicos Limite: Animais Idioma: Inglês Revista: Chinese Medical Journal Ano de publicação: 2005 Tipo de documento: Artigo