Comparison of Multidetector CT and Gadobutrol-Enhanced MR Imaging for Evaluation of Small, Solid Pancreatic Lesions
Korean Journal of Radiology
;
: 509-521, 2016.
Artigo
em Inglês
| WPRIM
| ID: wpr-29165
ABSTRACT
OBJECTIVE:
To compare multidetector computed tomography (MDCT) and MRI for lesion conspicuity, as well as the detection and characterization of small solid pancreatic lesions (SPLs). MATERIALS ANDMETHODS:
193 patients with small SPLs ( 0.05). The accuracies of CT and MRI for making a specific diagnosis were as follows 85.7% (210/245) vs. 86.9% (213/245), respectively, for reviewer 1 (p = 0.736), and 91.8% (225/245) vs. 93.5% (229/245), respectively, for reviewer 2 (p = 0.454).CONCLUSION:
MRI showed better lesion conspicuity than MDCT, but did not show significantly different diagnostic performance compared with MDCT for detecting and characterizing small SPLs.
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Assunto principal:
Pâncreas
/
Ductos Pancreáticos
/
Imageamento por Ressonância Magnética
/
Adenocarcinoma
/
Sensibilidade e Especificidade
/
Diagnóstico
/
Tomografia Computadorizada Multidetectores
Tipo de estudo:
Estudo diagnóstico
Limite:
Humanos
Idioma:
Inglês
Revista:
Korean Journal of Radiology
Ano de publicação:
2016
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS