Application of CTA and CAD\CAM techniques in mandible reconstruction with free fibula flap / 中华整形外科杂志
Chinese Journal of Plastic Surgery
; (6): 325-327, 2006.
Article
em Zh
| WPRIM
| ID: wpr-297152
Biblioteca responsável:
WPRO
ABSTRACT
<p><b>OBJECTIVE</b>To explore the application of computed tomographic angiography (CTA) and computer aided design\manufacture (CAD\CAM) techniques in mandible reconstruction with free fibula flap.</p><p><b>METHODS</b>7 cases of complex mandible defect were reconstructed with free fibula flap. Patients' lower extremity vasculature was evaluated by preoperative CTA examination; mandible tumor resection and reconstruction were simulated by CAD technique, the surgical template was manufactured with CAM technique preoperatively; and fibula flap was shaped according to surgical template during mandible reconstruction operation.</p><p><b>RESULTS</b>Preoperative CTA examination performed without complication, the desired anatomy was adequately demonstrated in all patients. All of flaps survived, patients' facial contour are symmetry approximately.</p><p><b>CONCLUSIONS</b>CTA and CAD\CAM techniques have important value for complex mandible reconstruction in selection of donor site, planning of operation and shaping of fibula flap.</p>