Your browser doesn't support javascript.
loading
Determination of salylic acid, syringic acid, benzoic acid and anthranilic acid in Radix Isatidis by HPCE / 中国中药杂志
China Journal of Chinese Materia Medica ; (24): 189-192, 2009.
Artigo em Chinês | WPRIM | ID: wpr-298434
ABSTRACT
<p><b>OBJECTIVE</b>To develop a simple and rapid capillary electrophoresis (CE) method for the separation and determination of four active organic acids including salicylic acid, syringic acid, benzoic acid, and anthranilic acid in Radix Isatidis.</p><p><b>METHOD</b>The HPCE system consisted of a fused-silica capillary column of 47.3 cm (38.3 cm to the detector) x50 microm i.d. and a mixture ofacetonitrile-borate buffer (15% acetonitrile, 25 mmol L(-1) borate, 15 mmol L(-1) beta-CD, pH 9.10) solution as the operating buffer. The applied voltage was 11.5 kV and the UV detection was set at 220 nm. The effects of the applied voltage, detection wavelength, and the pH of buffer, the concentration of buffer, acetonitrile and beta-CD were investigated.</p><p><b>RESULT</b>The linear calibration rang was 3.0-90 mg L(-1) (r=0.9994) for salylic acid, 4.0-120 mg L(-1) (r=0.9995) for syringic acid, 2.0-60 mg L(-1) (r=0.9998) for benzoic acid and 5.0-100 mg L(-1) (r=0.9992) for anthranilic acid. The recoveries of salylic acid, syringic acid, benzoic acid and anthranilic acid were 95.9%-102.6%, 98.6%-103.4%, 98.7%-104.1%, 96.1%-104.3% respectively. The detection limits of salylic acid, syringic acid, benzoic acid and anthranilic acid were 0.7, 1.1, 1.2 and 1.5 mg L(-1), respectively.</p>
Assuntos
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Modelos Lineares / Química / Reprodutibilidade dos Testes / Sensibilidade e Especificidade / Eletroforese Capilar / Ácido Benzoico / Ácido Salicílico / Isatis / Ortoaminobenzoatos / Ácido Gálico Tipo de estudo: Estudo diagnóstico / Estudo prognóstico Idioma: Chinês Revista: China Journal of Chinese Materia Medica Ano de publicação: 2009 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Modelos Lineares / Química / Reprodutibilidade dos Testes / Sensibilidade e Especificidade / Eletroforese Capilar / Ácido Benzoico / Ácido Salicílico / Isatis / Ortoaminobenzoatos / Ácido Gálico Tipo de estudo: Estudo diagnóstico / Estudo prognóstico Idioma: Chinês Revista: China Journal of Chinese Materia Medica Ano de publicação: 2009 Tipo de documento: Artigo