Your browser doesn't support javascript.
loading
Case-control study on methods of limb length control in hip arthroplasty / 中国骨伤
China Journal of Orthopaedics and Traumatology ; (12): 102-106, 2016.
Artigo em Chinês | WPRIM | ID: wpr-304337
ABSTRACT
<p><b>OBJECTIVE</b>To introduce a new measuring tool for measuring postoperative limb length exactly, and to provide a convenient and effective method to control limb length after total hip replacement.</p><p><b>METHODS</b>From January 2013 to September 2014, 102 patients undergoing primary unilateral hip replacement were divided into two groups experimental group and control group. There were 51 patients in the experimental group, including 25 males and 26 females, ranging in age from 37 to 92 years old, with an average of 60.41 years old. The patients in experimental group were treated with new method to control limb length. Other 51 patients in the control group, including 27 males and 24 females, ranging in age from 35 to 87 years old, with an average of 61.00 years old. The patients in the control group were treated with normal methods such as shuck test or limb touching. All the patients were operated by the same experienced surgeon. In the experimental group,total hip arthroplasties (THA) were performed on 35 patients with avascular necrosis of the femoral head or femoral neck fracture, and 16 patients were treated with hemiarthroplasty (HA). In the control group, 38 patients received THA and 13 patients received HA. On the anterior-posterior X-ray radiograph, several indexes were measured as follows the distance of bilateral femoral offset (a), the height from tip of great trochanter to the rotation center of the femoral head (b) and the vertical distance between the top of the minor trochanter and the two tear drops line (c). The leg length discrepancy can be assessed with three parameters as follows d1, the absolute value of the difference between the bilateral a values; d2, the difference between the bilateral b values; d3, the difference between the bilateral c values. The SPSS 21.0 was applied for the statistical analysis.</p><p><b>RESULTS</b>In the experimental and control groups, d1 were 4.49 mm and 7.32 mm (P = 0.013); d2 were 2.37 mm and 4.32 mm (P = 0.033); d3 were 3.32 mm and 6.08 mm (P = 0.031). The values of d1, d2 and d3 in the experimental group were significant smaller than those in the control group.</p><p><b>CONCLUSION</b>The new measuring tool and method can be used to control the limb length and offset effectively during operation.</p>
Assuntos
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Estudos de Casos e Controles / Artroplastia de Quadril / Desigualdade de Membros Inferiores / Métodos Tipo de estudo: Estudo observacional Limite: Adulto / Idoso / Aged80 / Feminino / Humanos / Masculino Idioma: Chinês Revista: China Journal of Orthopaedics and Traumatology Ano de publicação: 2016 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Estudos de Casos e Controles / Artroplastia de Quadril / Desigualdade de Membros Inferiores / Métodos Tipo de estudo: Estudo observacional Limite: Adulto / Idoso / Aged80 / Feminino / Humanos / Masculino Idioma: Chinês Revista: China Journal of Orthopaedics and Traumatology Ano de publicação: 2016 Tipo de documento: Artigo