Your browser doesn't support javascript.
loading
Utility of echocardiographic tissue synchronization imaging to redirect left ventricular epicardial lead placement for cardiac resynchronization therapy / 中华医学杂志(英文版)
Chinese Medical Journal ; (24): 4222-4226, 2013.
Artigo em Inglês | WPRIM | ID: wpr-327599
ABSTRACT
<p><b>BACKGROUND</b>Cardiac resynchronization therapy (CRT) with biventricular pacing has demonstrated cardiac function improvement for treating congestive heart failure (HF). It has been documented that the placement of the left ventricular lead at the longest contraction delay segment has the optimal CRT benefit. This study described follow-up to surgical techniques for CRT as a viable alternative for patients with heart failure.</p><p><b>METHODS</b>Between April 2007 and June 2012, a total of 14 consecutive heart failure patients with New York Heart Association (NYHA) Class III-IV underwent left ventricular epicardial lead placements via surgical approach. There were eight males and six females, aged 36 to 79 years ((59.6 ± 9.2) years). The mean left ventricular ejection fraction (LVEF) was (33.6 ± 7.4)%. All patients were treated with left ventricular systolic dyssynchrony and underwent left ventricular epicardial lead placements via a surgical approach. Tissue Doppler imaging (TDI) and intraoperative transesophageal echocardiography were used to assess changes in left heart function and dyssynchronic parameters. Also, echo was used to select the best site for left ventricular epicardial lead placement.</p><p><b>RESULTS</b>Left ventricular epicardial leads were successfully implanted in the posterior or lateral epicardial wall without serious complications in all patients. All patients had reduction in NYHA score from III-IV preoperatively to II-III postoperatively. The left ventricular end-diastolic diameter (LVEDD) decreased from (67.9 ± 12.7) mm to (61.2 ± 7.1) mm (P < 0.05), and LVEF increased from (33.6 ± 7.4)% to (42.2 ± 8.8)% (P < 0.05). Left ventricular intraventricular dyssynchrony index decreased from (148.4 ± 31.6) ms to (57.3 ± 23.8) ms (P < 0.05).</p><p><b>CONCLUSIONS</b>Minimally invasive surgical placement of the left ventricular epicardial lead is feasible, safe, and efficient. TDI can guide the epicardial lead placement to the ideal target location.</p>
Assuntos
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Terapêutica / Ecocardiografia / Resultado do Tratamento / Terapia de Ressincronização Cardíaca / Insuficiência Cardíaca / Métodos Limite: Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Inglês Revista: Chinese Medical Journal Ano de publicação: 2013 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Terapêutica / Ecocardiografia / Resultado do Tratamento / Terapia de Ressincronização Cardíaca / Insuficiência Cardíaca / Métodos Limite: Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Inglês Revista: Chinese Medical Journal Ano de publicação: 2013 Tipo de documento: Artigo