ABSTRACT
Quantitative models were established to analyze the content of chlorogenic acid and soluble solid content in the liquid-liquid extraction of Reduning injection by near-infrared (NIR) spectroscopy. Seven batches of extraction solution from the liquid-liquid extraction of Lonicerae Japonicae Flos and Artemisiae Annuae Herba were collected and NIR off-line spectra were acquired. The content of chlorogenic acid and soluble solid content were determined by the reference methods. The partial least square (PLS) and artificial neural networks (ANN) were used to build models to predict the content of chlorogenic acid and soluble solid content in the unknown samples. For PLS models, the R2 of calibration set were 0.9872, 0.9812, RMSEC were 0.1533, 0.7943, the R2 of prediction set were 0.9837, 0.9733, RMSEP were 0.2464, 1.2594, RSEP were 3.25%, 3.31%, for chlorogenic acid and soluble solid content, respectively. For ANN models, the R2 of calibration set were 0.9903, 0.9882, RMSEC were 0.0974, 0.4543, the R2 of prediction set were 0.9868, 0.9699, RMSEP were 0.1920, 0.9427, RSEP were 2.61%, 2.75%, for chlorogenic acid and soluble solid content, respectively. Both the RSEP values of chlorogenic acid and soluble solid content were lower than 6%, which can satisfy the quality control standard in the traditional Chinese medicine production process. The RSEP values of ANN models were lower than PLS models, which indicated the ANN models had better predictive performance for chlorogenic acid and soluble solid content. The established method can rapidly measure the content of chlorogenic acid and soluble solid content. The method is simple, accurate anc reliable, thus can be used for quality control of the liquid-liquid extraction of Reduning injection.
Assuntos
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Controle de Qualidade / Padrões de Referência / Medicamentos de Ervas Chinesas / Análise dos Mínimos Quadrados / Ácido Clorogênico / Redes Neurais de Computação / Espectroscopia de Luz Próxima ao Infravermelho / Extração Líquido-Líquido / Injeções / Métodos Tipo de estudo: Estudo prognóstico Idioma: Chinês Revista: China Journal of Chinese Materia Medica Ano de publicação: 2015 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Controle de Qualidade / Padrões de Referência / Medicamentos de Ervas Chinesas / Análise dos Mínimos Quadrados / Ácido Clorogênico / Redes Neurais de Computação / Espectroscopia de Luz Próxima ao Infravermelho / Extração Líquido-Líquido / Injeções / Métodos Tipo de estudo: Estudo prognóstico Idioma: Chinês Revista: China Journal of Chinese Materia Medica Ano de publicação: 2015 Tipo de documento: Artigo