Latest advances of the cause and preventive strategies of adjacent vertebral body fracture after percutaneous vertebroplasty / 中国骨伤
China Journal of Orthopaedics and Traumatology
;
(12): 792-795, 2010.
Artigo
em Chinês
| WPRIM
| ID: wpr-332825
ABSTRACT
Percutaneous vertebroplasty (PVP) is widely used as an effective treatment for compression fracture, additional adjacent vertebral body fractures are frequently reported after operation, but the relationship between the vertebroplasty and adjacent vertebral body fracture remains unknown. The possible causes of refracture after operation include mechanical force factor, bone cement and clinical factors. Except for the changes of stress and stiffness of the adjacent vertebral bodies, the extravasation of cement and osteoporosis itself of the vertebral bodies should be concerned about. To aim at above-mentioned reasons, simultaneously, preventive strategies, such as prophylactic cement injection into adjacent non-fractured vertebrae, additional PVP and injectable copolymer hydrogel are approached in this review.