Your browser doesn't support javascript.
loading
Clinical application of dual-source computed tomographic urography using dual-energy virtual non enhanced computed tomography / 中国医学科学院学报
Acta Academiae Medicinae Sinicae ; (6): 649-654, 2010.
Artigo em Chinês | WPRIM | ID: wpr-341482
ABSTRACT
<p><b>OBJECTIVE</b>To evaluate the clinical feasibility of dual-source computed tomographic urography using dual-energy virtual non-enhanced CT.</p><p><b>METHODS</b>Totally 240 patients received dual-source CT, which included true non-enhanced CT (TNCT) , nephrographic phase scanning with dual-energy mode (100kVp/230mAs and Sn140kVp/178mAs) , and excretory phase scanning. A contrast bolus injection of 100 ml (370 mgI/ml) contrast agent was applied (4.5ml/s) , followed by 100ml normal saline (4.5ml/s) . Virtual non-enhanced CT (VNCT) image sets were reformatted from 'Liver VNC ' software. The mean CT number, noise, signal to noise ratio (SNR) , image quality, and radiation dose were compared between TNCT and VNCT image sets.</p><p><b>RESULTS</b>There was no significant difference in mean CT numbers of all organs (P>0.05) . However, VNCT images had significantly lower noise and higher SNR than TNCT images (both P<0.05) . Image quality of VNCT was lower than that of TNCT without significant difference (P>0.05) . Radiation dose of nephrographic phase with dual-energy mode was significantly higher than that of TNCT and excretory phase scanning (P<0.05) .</p><p><b>CONCLUSION</b>Dual-energy VNCT requires less radiation dose and therefore has a potential to replace TNCT in the dual-source CT urography.</p>
Assuntos
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Doses de Radiação / Urografia / Tomografia Computadorizada por Raios X / Imagem Radiográfica a Partir de Emissão de Duplo Fóton / Reprodutibilidade dos Testes / Sensibilidade e Especificidade / Razão Sinal-Ruído / Métodos Tipo de estudo: Estudo diagnóstico Limite: Adolescente / Adulto / Idoso / Aged80 / Feminino / Humanos / Masculino Idioma: Chinês Revista: Acta Academiae Medicinae Sinicae Ano de publicação: 2010 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Doses de Radiação / Urografia / Tomografia Computadorizada por Raios X / Imagem Radiográfica a Partir de Emissão de Duplo Fóton / Reprodutibilidade dos Testes / Sensibilidade e Especificidade / Razão Sinal-Ruído / Métodos Tipo de estudo: Estudo diagnóstico Limite: Adolescente / Adulto / Idoso / Aged80 / Feminino / Humanos / Masculino Idioma: Chinês Revista: Acta Academiae Medicinae Sinicae Ano de publicação: 2010 Tipo de documento: Artigo