Quantitative comparison of calcium hydroxide removal by EndoActivator, ultrasonic and ProTaper file agitation techniques: an in vitro study / 华中科技大学学报(医学)(英德文版)
Journal of Huazhong University of Science and Technology (Medical Sciences) ; (6): 142-145, 2013.
Artigo em Inglês | WPRIM | ID: wpr-343128
ABSTRACT
Calcium hydroxide (CH) dressing residues can compromise endodontic sealing. This study aimed to evaluate the amount of remaining CH in root canals after mechanical removal by four groups of irrigation techniques including needle irrigation only, ProTaper file, EndoActivator, and ultrasonic file. Fifteen extracted single-rooted teeth were collected and used for all four groups. The samples were firstly prepared by ProTaper rotary instruments, and then sectioned longitudinally through the long axis of the root canals, followed by final reassembling by wires. CH was kept in the canals for 7 days setting. The removal procedure began with 5 mL of 2.5% sodium hypochlorite (NaOCl) followed by 1 mL of 17% ethylenediaminetetraacetic acid and a final irrigation with 5 mL of 2.5% NaOCl solution for all groups. No additional agitation of the irrigant was performed in group 1, while agitation for 20 s between irrigants was done with F2 ProTaper rotary file in group 2, EndoActivator with tip size 25/.04 in group 3 and by an ultrasonic file 25/.02 in group 4. The total activation time was 60 s. The roots were then disassembled and captured by digital camera. The ratio of CH coated surface area to the surface area of the whole canal as well as each third of the canal was calculated. The data were statistically analyzed by one-way ANOVA using post hoc Tukey test. Results showed that none of the four techniques could remove all CH. No significant difference was found between EndoActivator and ultrasonic techniques. However, they both removed significantly more CH than ProTaper and needle irrigation (P=0.0001). In conclusion, the sonic and ultrasonic agitation techniques were more effective in removing intracanal medicaments than the ProTaper rotary file and needle irrigation in all thirds of the canal.
Assuntos
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Irrigantes do Canal Radicular / Sonicação / Técnicas In Vitro / Hidróxido de Cálcio / Química / Preparo de Canal Radicular / Análise de Falha de Equipamento / Instrumentos Odontológicos / Cavidade Pulpar / Desenho de Equipamento Limite: Humanos Idioma: Inglês Revista: Journal of Huazhong University of Science and Technology (Medical Sciences) Ano de publicação: 2013 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Irrigantes do Canal Radicular / Sonicação / Técnicas In Vitro / Hidróxido de Cálcio / Química / Preparo de Canal Radicular / Análise de Falha de Equipamento / Instrumentos Odontológicos / Cavidade Pulpar / Desenho de Equipamento Limite: Humanos Idioma: Inglês Revista: Journal of Huazhong University of Science and Technology (Medical Sciences) Ano de publicação: 2013 Tipo de documento: Artigo