Imaging diagnosis for fatty liver: a systematic review / 中国医学科学院学报
Acta Academiae Medicinae Sinicae ; (6): 580-584, 2004.
Artigo em Chinês | WPRIM | ID: wpr-343805
ABSTRACT
<p><b>OBJECTIVE</b>To systematically assess imaging diagnostic tests for fatty liver and provide a decision-making basis for clinical diagnosis and screening.</p><p><b>METHODS</b>Electronic searches were conducted on the Chinese Biomedical Database, PubMed, and EMBASE, combining with manually searching of Chinese literature. All searches were completed until November 2002. All studies which evaluated imaging diagnostic test of human fatty liver were included. Data of diagnostic accuracy in the included studies were extracted, and methodological quality of the studies was assessed independently by two reviewers according to the established quality standard. Quantitative analysis or qualitative description were performed based on available data.</p><p><b>RESULTS</b>Of 13 studies that met the eligibility criteria, 10 studies evaluated the diagnostic accuracy of B-mode ultrasound, 3 studies evaluated contrast-enhanced (helical) CT. To assess 7 diagnostic test studies for fatty liver that used liver biopsy as reference test the pooled sensitivity of B-mode ultrasound was 0.89 (95% confidence interval 0.87-0.92), specificity was 0.94 (95% confidence interval 0.92-0.96) and the Q value was 0.90 by adjusted SROC method. To assess 2 diagnostic test studies for fatty liver that used CT as reference test the pooled sensitivity, specificity, and Q value were 0.92 (95% confidence interval 0.89-0.96), 0.88 (95% confidence interval 0.84-0.92), and 0.90 respectively by adjusted SROC method.</p><p><b>CONCLUSIONS</b>B-mode ultrasound method can be regarded as an effective method for fatty liver diagnosis and screening. The methodologic quality of diagnostic test needs to be improved.</p>
Assuntos
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Diagnóstico por Imagem / Valor Preditivo dos Testes / Ultrassonografia / Sensibilidade e Especificidade / Tomografia Computadorizada Espiral / Diagnóstico / Fígado Gorduroso / Fígado Tipo de estudo: Estudo diagnóstico / Estudo prognóstico / Pesquisa qualitativa / Revisões Sistemáticas Avaliadas Limite: Feminino / Humanos / Masculino Idioma: Chinês Revista: Acta Academiae Medicinae Sinicae Ano de publicação: 2004 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Diagnóstico por Imagem / Valor Preditivo dos Testes / Ultrassonografia / Sensibilidade e Especificidade / Tomografia Computadorizada Espiral / Diagnóstico / Fígado Gorduroso / Fígado Tipo de estudo: Estudo diagnóstico / Estudo prognóstico / Pesquisa qualitativa / Revisões Sistemáticas Avaliadas Limite: Feminino / Humanos / Masculino Idioma: Chinês Revista: Acta Academiae Medicinae Sinicae Ano de publicação: 2004 Tipo de documento: Artigo