Your browser doesn't support javascript.
loading
The clinical value of cartilaginous surface and corresponding osseous contour of patellofemoral joint / 中华外科杂志
Chinese Journal of Surgery ; (12): 1722-1725, 2010.
Artigo em Chinês | WPRIM | ID: wpr-346366
ABSTRACT
<p><b>OBJECTIVE</b>to investigate if the cartilaginous surface and corresponding osseous contour of the patellofemoral joint match in the axial plane for providing theoretical basis with evaluating alignment of patellofemoral joint and designing the part of patellofemoral joint in knee prosthesis.</p><p><b>METHODS</b>from January 2009 to March 2010, 9 human cadaver knees were prepared, which chandra of patellofemoral joint didn't degenerate. Each specimen was sectioned in the axial plane at 20° to 30° knee flax. The cross-sections revealed characteristics in the bony anatomy and corresponding articular surface geometry of the patellofemoral joint in the axial plane. Evaluating parameters included osseous patella congruence angle (OPCA), chondral patella congruence angle (CPCA), patella chondral convex point parameter (PCCPP), patella subchondral osseous convex point parameter (PSOCPP), the parameters of the deepest (chondral or osseous) point of the intercondylar sulcus. After that, the osseous and cartilaginous contours and subchondral osseous contours of the patella in the axial plane were analyzed through MRI data of 11 patients who didn't degenerate in patellofemoral joint cartilage. Parameters as same as cadaver knees were compared.</p><p><b>RESULTS</b>data from specimens of OPCA was (-4.5 ± 1.1)°, CPCA was (0.5 ± 0.8)°, PCCPP was 1.13 ± 0.11, PSOCPP was 1.67 ± 0.14, PCDPIS was 1.35 ± 0.28, PODPIS was 1.38 ± 0.33. Date from MRI of OPCA was (-3.8 ± 1.4)°, CPCA was (0.7 ± 1.0)°, PCCPP was 1.05 ± 0.21, PSOCPP was 1.73 ± 0.18, PCDPIS was 1.41 ± 0.21, PODPIS was 1.37 ± 0.27. The patella exhibited significant differences in the bony vs. chondral anatomy (P < 0.05), but the intercondylar sulcus nearly match in the bony vs. chondral anatomy.</p><p><b>CONCLUSIONS</b>the cartilaginous surface and corresponding osseous contour of the patella don't match in the patellofemoral joint axial plane, but that of the trochlea nearly matches. This is very important for accurately evaluating alignment of patellofemoral joint because the normal osseous alignment of patellofemoral joint don't represent the normal alignment and helpful for designing the part of patellofemoral joint in knee prosthesis.</p>
Assuntos
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Patela / Fenômenos Biomecânicos / Cartilagem Articular / Articulação Patelofemoral / Fêmur Limite: Humanos Idioma: Chinês Revista: Chinese Journal of Surgery Ano de publicação: 2010 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Patela / Fenômenos Biomecânicos / Cartilagem Articular / Articulação Patelofemoral / Fêmur Limite: Humanos Idioma: Chinês Revista: Chinese Journal of Surgery Ano de publicação: 2010 Tipo de documento: Artigo