Wavefront Aberration Changes after the Instillation of Artificial Tear in Dry Eyes
Journal of the Korean Ophthalmological Society
;
: 186-191, 2006.
Artigo
em Coreano
| WPRIM
| ID: wpr-34736
ABSTRACT
PURPOSE:
To identify the effects of artificial tear instillation on tear film changes using wavefront aberrations.METHODS:
Artifical tear was instilled every 2 hours for 14 days into 20 normal eyes and 20 dry eyes. The changes in tear film using wavefront aberrations were analyzed 1 minute after the final instillation of artifical tear.RESULTS:
In dry eyes, total wavefront aberration and total high order wavefront aberration decreased significantly (p<0.05). In normal eyes, total wavefront aberration and high order wavefront aberration did not decrease.CONCLUSIONS:
Stabilization of the tear film after instillation of artificial tear may be responsible for the decrease of wavefront abberation in dry-eye patients.