Your browser doesn't support javascript.
loading
Early and mid-term results after 17 mm St Jude Regent mechanical valve replacement in 44 patients with small aortic root / 南方医科大学学报
Article em Zh | WPRIM | ID: wpr-355015
Biblioteca responsável: WPRO
ABSTRACT
<p><b>OBJECTIVE</b>To analyze the changes in the cardiac function after St. Jude Regent mechanical valve replacement and assess the prosthesis-patient matching.</p><p><b>METHODS</b>From October 2007 to March 2009, 44 patients received implantation of 17 mm St. Jude aortic prostheses in our hospital. The patients were followed up for clinical symptoms, signs, electrocardiogram (ECG), echocardiogram and cardiac functions, and the results were compared with those of randomly selected 44 patients receiving 21 mm St. Jude aortic prostheses.</p><p><b>RESULTS</b>In 17 mm St Jude Medica Regent valve group, 8 patients presented with ECG ST segment changes, 3 complained of chest tightness, 3 had occasional chest pain and discomfort, and 8 had grade II and 4 grade III cardiac function. In 21 mm St Jude Medical Regent valve group, 6 patients had ECG ST segment changes, 2 complained of chest tightness, 2 reported occasional chest pain and discomfort, 11 had grade II and 2 grade III cardiac function. No significant differences were found in these indices between the two groups (P=0.32). Compared with those before operation, the two groups showed significant improvements in the left ventricular end-diastolic diameter, left ventricular posterior wall thickness, left ventricular mass index, and aortic pressure gradient (P<0.05). A significant increase in the left ventricular ejection fraction occurred 6-12 months after operation, but without statistical difference between the two groups (P>0.05).</p><p><b>CONCLUSION</b>For underweight patients (<60 kg) and those with small body surface area (<1.6 cm(2)), 17 mm St. Jude Medical Regent valve prosthesis may produce good therapeutic effect, and some indices are even close to those after placement of 21 mm St. Jude Medical Regent valve prosthesis. No obvious prosthesis-patient mismatch occurs after the placement of the 17 mm valve prosthesis and aortic valve ring expansion is not necessary.</p>
Assuntos
Texto completo: 1 Índice: WPRIM Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Complicações Pós-Operatórias / Cirurgia Geral / Próteses Valvulares Cardíacas / Diagnóstico por Imagem / China / Epidemiologia / Seguimentos / Ultrassonografia Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Adolescent / Adult / Child / Child, preschool / Female / Humans / Male País/Região como assunto: Asia Idioma: Zh Revista: Journal of Southern Medical University Ano de publicação: 2010 Tipo de documento: Article
Texto completo: 1 Índice: WPRIM Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Complicações Pós-Operatórias / Cirurgia Geral / Próteses Valvulares Cardíacas / Diagnóstico por Imagem / China / Epidemiologia / Seguimentos / Ultrassonografia Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Adolescent / Adult / Child / Child, preschool / Female / Humans / Male País/Região como assunto: Asia Idioma: Zh Revista: Journal of Southern Medical University Ano de publicação: 2010 Tipo de documento: Article