Your browser doesn't support javascript.
loading
Surgery of Descending Thoracic Aortic Aneurysms with Use of a Centrifugal Pump. Usefulness of the Autotransfusion System / 日本心臓血管外科学会雑誌
Japanese Journal of Cardiovascular Surgery ; : 103-106, 1993.
Artigo em Japonês | WPRIM | ID: wpr-365890
ABSTRACT
We reviewed the results of 14 patients who underwent the operation of thoracic aneurysms using a centrifugal pump. Nine patients had atherosclerotic aneurysms and 5 had aortic dissections. The autotransfusion system (ATS) was used to keep hemodynamic stability by rapid transfusion. The ATS consisted of a roller pump, a 2, 000ml reservoir and a heat exchanger. Two mg/kg of heparin was given to the patients to keep ACT over 400 seconds. All patients survived. Body temperature increased 0.08±0.59°C during bypass with the ATS, and no patients showed hemodynamic instability after aneurysmotomy under the help of the ATS. We conclude that 1) the centrifugal pump is a useful and safe assisting means for the surgery of thoracic aneurysms, 2) the autotransfusion system has advantages as follows keeping stable circulation and preventing loss of body temperature during bypass.
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Japonês Revista: Japanese Journal of Cardiovascular Surgery Ano de publicação: 1993 Tipo de documento: Artigo