Your browser doesn't support javascript.
loading
Mechanical Properties of F Plate in Intraarticular Calcaneal Fractures
Journal of the Korean Fracture Society ; : 167-172, 2004.
Artigo em Coreano | WPRIM | ID: wpr-36969
ABSTRACT

PURPOSE:

We evaluated the mechanical properties of F plate fixation comparing with Y plate and a screw fixation for the intraarticular calcaneal fractures using synthetic bones. MATERIALS AND

METHODS:

Using 12 synthetic calcaneal bones, newly designed F plate was compared with the Y-plate, most commonly used, regarding the change of Bohler angle and the displacement of the thalamic fragments of the calcaneus after axial compressive loading by Instron 6022.

RESULTS:

Y plate fixation lost 8degrees of Bohler angle in average after axial compressive load and 2.6degrees in F plate fixation. Thalamic fragments were displaced 1.72 mm in average in Y plate fixation group and 0.73 mm in F plate fixation group.

CONCLUSION:

F plate offered more firm fixation than Y plate in the intraarticular calcaneal fracture in the aspect of maintaining the Bohler angle and preventing displacement of the thalamic fragments of calcaneus against axial compressive loading.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Calcâneo / Fraturas Intra-Articulares Idioma: Coreano Revista: Journal of the Korean Fracture Society Ano de publicação: 2004 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Calcâneo / Fraturas Intra-Articulares Idioma: Coreano Revista: Journal of the Korean Fracture Society Ano de publicação: 2004 Tipo de documento: Artigo