A 62 year-old man presented with severe septic shock complicated by prosthetic graft infection, 7 years after aortic root replacement with a Freestyle stentless valve and graft replacement of the ascending aorta. We initially managed the patient with antimicrobial therapy for 2 months and subsequently surgery was performed, replacing the infected aortic graft with rifampicin-bonded prostheses, and added omentopexy. The infection was cured and has not recurred.