Your browser doesn't support javascript.
loading
320 slice CT electrocardiograph-gating double phase cardiac function angiography scan mode:a preliminary investigation of one-stop-shop exam / 中华放射学杂志
Chinese Journal of Radiology ; (12): 22-25, 2011.
Artigo em Chinês | WPRIM | ID: wpr-384787
ABSTRACT
Objective To explore the feasibility of evaluating cardiac structure, coronary artery,pulmonary artery and cardiac function in one single scan by 320-row CT ECG-gated double phase cardiac function scan mode. MethodsForty patients underwent the 320-detector row CT double phase cardiovascular angiography. The pulmonary phase and aortic phase were reconstructed in order to evaluate the pulmonary and coronary artery. MPR reconstructions of both pulmonary and aortic phase were used to analyze the function of the two ventricles. And the results of the cardiac function were compared with those of transthoracic echocardiography. Thirty-five cases could be analyzed and diagnosed, while the other 5 cases had to be given up because of the poor imaging quality. The mean heart rate was (71.2 ± 11.2) beat per min (bpm). No arrhythmia case included. Results ( 1 ) Pulmonary embolism were diagnosed in 11 cases,coronary artery disease (CAD) were found in 5 cases, while post-stent implantation were observed in 7 cases. Six cases of congenital heart disease were diagnosed with 3 ASD and 3 primary pulmonary hypertension. Another one was diagnosed with left atrial myxoma, and 5 cases were pulmonary embolism associated with CAD. All of above cases were verified by final clinical diagnosis. (2) The heart function parameters including LVEDd , RVEDd, LVESd, RVESd and LVEF were (36.7 ±3.3), (43.3 ± 3.4) mm,(31.6±5.1), (41.3 ±5.1) mm and (47.1 ±15.1) for CT, while those were (40.3 ±3.1), (47.3 ±4.2) mm,(37.3 ±5.6), (45.3 ±3.3) mm,and (46.0 ± 14.8) for ultrasound, respectively. The CT results were correlated with the ultrasound ( n = 35, r = 0.886-0.988, P < 0.01 ). (3) The average radiation exposure was ( 5.4 ± 0.5 ) mSv. Conclusions 320-row CT ECG-gated double phase cardiac function scan mode is feasible for the "one-stop-shop" examination of the cardiovascular disease. This noninvasive method is recommended for the diagnosis, differential diagnosis, treatment and prognosis of cardiovascular disease.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Radiology Ano de publicação: 2011 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Radiology Ano de publicação: 2011 Tipo de documento: Artigo