Your browser doesn't support javascript.
loading
Evaluation of left ventricular systolic function of cardiomyopathy patients with stereo three-dimensional echocardiography / 中华超声影像学杂志
Chinese Journal of Ultrasonography ; (12): 553-556, 2010.
Artigo em Chinês | WPRIM | ID: wpr-388427
ABSTRACT
Objective To evaluate the accuracy and value of measurement of left ventricular systolic function in dilated cardiomyopathy (DCM) and hypertrophic cardiomyopathy (HCM) patients with stereo three-dimensional echocardiography (S3 DE). Methods End-diastolic volume (EDV), end-systolic volume (ESV),stroke volume(SV) and ejection fraction(EF) of the left ventricle were measured with M-mode echocardiography(ME),two-dimensional echocardiography(2DE) and S3DE in DCM patientsC20 cases). HCM patients(20 cases),and normal controls(20 cases). The different results among the three groups or three methods were analyzed. Results (①In all the three groups,the results of EDV,ESV,and SV obtained with ME were significantly higher than those obtained with S3DE( P <0. 01). Only in normal group( P <0. 01) and HCM group ( P <0. 05) ,the results of EF obtained with ME and 2DE were significantly higher than that obtained with S3DE. ②By S3DE,compared with normal group,EDV,ESV were increased and EF was decreased obviously in DCM group (all P <0. 01); while in HCM group, only SV was significantly higher( P < 0. 01). ③EDV, ESV, and EF measured by S3DE were correlated and fit well with those measured by 2DE(r = 0.778,0.876, 0.932;R2 =0.605,0.767,0.869;all P <0.01). ④Within HCM group,excluding the impact of heart rate,cardiac output (CO) was highly correlated with SV( r = 0. 987,P < 0. 01). Conclusions S3DE can real-time display the stereo structure of the heart, and accurately and reliably assess the left ventricular systolic function, with a priority over traditional ME and 2DE methods. EDV,ESV, and EF are still effective indicators for the clinical assessment of left ventricular systolic function. SV obtained with S3DE will be expected to be the more sensitive and accurate value in assessing left ventricular systolic function in patients with early-stage cardiomyopathy.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Ultrasonography Ano de publicação: 2010 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Ultrasonography Ano de publicação: 2010 Tipo de documento: Artigo