Your browser doesn't support javascript.
loading
Argon plasma coagulation combined with bifurcated metal stents for treatment of airway stenosis in the carinal region A 16-case analysis / 中国组织工程研究
Chinese Journal of Tissue Engineering Research ; (53): 5995-6000, 2009.
Artigo em Chinês | WPRIM | ID: wpr-406012
ABSTRACT
A total of 16 patients with airway stenosis including benign lesion (n=4) and malignant disease (n=12) were treated with argon plasma coagulation (APC) and Z-type covered retrievable metallic stent.L-and I-type stents were placed by guidance of brenchoscope,while Y-type stent was placed by the guidance of both bronchoscope and fluoroscope.Airway stenosis was from (58.8 +9.1)% before APC to (7.5±2.4)% after APC in tracheal,from (67.4±7.4)% to (19.4±4.1)% in left main bronchus,from (69.6±8.9)% to (27.6±5.4)% in right main bronchus.Symptoms of chest distress and breathlessness were improved remarkably,tachypnea indexes were decreased,but Kamofsky performance scope were increased.Twelve stents were successfully installed by the first time,including 9 Y-shape;otherwise,4 stents failed to be installed because the carinal was too wide to insert the Y-shape stent in two patients with lung cancer,finally,L+I type stents were used.Median survival time after successful stenting was 10 months,and mean time was 13 months.APC combined with bifurcated metal stants relieved obstruction and improved quality of life.
Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Tissue Engineering Research Ano de publicação: 2009 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Tissue Engineering Research Ano de publicação: 2009 Tipo de documento: Artigo