Your browser doesn't support javascript.
loading
Physical characteristics of synovial fluid nano-particles in knee osteoarthritis detected with quasi-elasticity laser scattering / 中国组织工程研究
Article em Zh | WPRIM | ID: wpr-408000
Biblioteca responsável: WPRO
ABSTRACT
BACKGROUND:There is a great difference of grade size of macrobead in various joint diseases; therefore, it can be used to determine state of joint diseases initially.OBJECTTVE : To explore the physical properties of synovial fluid nano-particles and their correlations with the occurrence of knee osteoarthritis (KOA).DESIGN: Controlled experimental study based on synovial fluid samples.PARTICIPANTS: A total of 99 synovial fluid samples were collected from normal subjects and KOA patients with various KOA severities. Among them, 41 were normal synovial fluids, 58 were KOA.METHODS: Synovial fluid samples from individuals with and without KOA were obtained. Using the technology of quasi-elastic laser scattering, nano-particle size and its distribution were estimated, and the dynamic/static light scattering spectrometric analyzer allowed the measurement of particles Zeta potentials. A correlation analysis between the particle size, Zeta potentials and the onset of KOA was attempted.MAIN OUTCOME MEASURES:① Grade size and distribution of microsome in synovial fluid;② Zeta potentials and distribution of microsome in synovial fluid; ③ grade size and clinical correlation of microsome in synovial fluid.RESULTS: ① The mean nano-particle diameter in the synovial fluid of KOA patients were significantly greater than those of normal joints [(297±84), (63±23) nm, P < 0.001]. The distribution curve of KOA synovial fluid nano-particle size was normal knee and (-15.84 ±3.34) mV of KOA patients, and there was a significant difference (P < 0.001). This suggestedthat the Zeta potentials in the synovial fluid of KOA patients were significantly greater than those of normal joints. ③ The average particle size and Zeta potential of synovial fluid strongly correlated with the integrity of the joint of KOA (rp =0.797 2,0.631 9, P< 0.01).CONCLUSION: The nano-particle size and Zeta potential of synovial fluid are significantly correlated with the development of KOA, and this can reflect the severity of KOA.
Texto completo: 1 Índice: WPRIM Idioma: Zh Revista: Chinese Journal of Tissue Engineering Research Ano de publicação: 2007 Tipo de documento: Article
Texto completo: 1 Índice: WPRIM Idioma: Zh Revista: Chinese Journal of Tissue Engineering Research Ano de publicação: 2007 Tipo de documento: Article