Percutaneous cardiopulmonary support to treat suspected venous air embolism with cardiac arrest during open eye surgery: a case report / 대한마취과학회지
Korean Journal of Anesthesiology
;
: 350-353, 2014.
Artigo
em Inglês
| WPRIM
| ID: wpr-41281
ABSTRACT
We report a case of possible venous air embolism (VAE) during trans pars plana vitrectomy with air-fluid exchange of the vitreous cavity. Shortly after initiation of air-fluid exchange, decreases in end-tidal CO2, oxygen saturation, and blood pressure were observed. The patient rapidly progressed to cardiac arrest unresponsive to cardiopulmonary resuscitation, and recovered after the application of percutaneous cardiopulmonary support. Prompt termination of air infusion is needed when VAE is suspected during air-fluid exchange, and extracorporeal life support should be considered in fatal cases. Although the incidence is rare the possibility of VAE during ophthalmic surgery clearly exists, and therefore awareness and vigilant monitoring seem critical.
Texto completo:
DisponíveL
Índice:
WPRIM (Pacífico Ocidental)
Assunto principal:
Oxigênio
/
Procedimentos Cirúrgicos Oftalmológicos
/
Vitrectomia
/
Pressão Sanguínea
/
Incidência
/
Reanimação Cardiopulmonar
/
Embolia Aérea
/
Parada Cardíaca
Tipo de estudo:
Estudo de incidência
/
Estudo prognóstico
Limite:
Humanos
Idioma:
Inglês
Revista:
Korean Journal of Anesthesiology
Ano de publicação:
2014
Tipo de documento:
Artigo
Similares
MEDLINE
...
LILACS
LIS