Your browser doesn't support javascript.
loading
Is small tidal volume with low positive end expiratory pressure during one-lung ventilation an effective ventilation method for endoscopic thoracic surgery? / 대한마취과학회지
Korean Journal of Anesthesiology ; : 329-333, 2014.
Artigo em Inglês | WPRIM | ID: wpr-41285
ABSTRACT

BACKGROUND:

The present study will focus on the rationale for the use of small tidal volume with 6 cmH2O positive end expiratory pressure (PEEP) with the changes of arterial oxygen tension, plateau airway pressure, and static lung compliance during one lung ventilation for endoscopic thoracic surgery.

METHODS:

Forty-three patients were intubated with a double-lumen endobronchial tube. After positioning the patients in the lateral decubitus, one-lung ventilation was started with 100% oxygen, tidal volume 10 ml/kg without PEEP; arterial oxygen tension, plateau airway pressure, and static compliance were checked as baseline values (T0). Fifteen minutes later, same parameters were measured (T15). The tidal volume had changed to 6 ml/kg with 6 cmH2O PEEP. Fifteen minutes later, the same parameters were measured (T30).

RESULTS:

Oxygen tension had decreased at T15 (282.1 +/- 83.4 mmHg) compared to T0 (477.2 +/- 82.4 mmHg) (P < 0.0001), but was maintained at T30 (270.4 +/- 81.9 mmHg). There was no difference in peak inspiratory pressure at T15 or T30 compared to T0, plateau airway pressure was increased at T15 and T30 (P < 0.05) and static lung compliance was decreased at T15 and T30 (P < 0.0001).

CONCLUSIONS:

In carrying out one-lung ventilation for thoracic surgery using an endoscope, the addition of a PEEP of 6 cmH2O in the dependent lung, while reducing the tidal volume of 6 ml/kg, both oxygen tension and lung compliance are maintained without increasing the plateau airway pressure. Protective lung ventilation is useful for one lung ventilation.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Oxigênio / Cirurgia Torácica / Toracoscopia / Ventilação / Volume de Ventilação Pulmonar / Complacência Pulmonar / Respiração com Pressão Positiva / Complacência (Medida de Distensibilidade) / Endoscópios / Ventilação Monopulmonar Limite: Humanos Idioma: Inglês Revista: Korean Journal of Anesthesiology Ano de publicação: 2014 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Oxigênio / Cirurgia Torácica / Toracoscopia / Ventilação / Volume de Ventilação Pulmonar / Complacência Pulmonar / Respiração com Pressão Positiva / Complacência (Medida de Distensibilidade) / Endoscópios / Ventilação Monopulmonar Limite: Humanos Idioma: Inglês Revista: Korean Journal of Anesthesiology Ano de publicação: 2014 Tipo de documento: Artigo