Your browser doesn't support javascript.
loading
Hemodynamics assessment by perfusion computed tomography in a canine model of portal hypertension / 中华普通外科杂志
Chinese Journal of General Surgery ; (12): 402-405, 2011.
Artigo em Chinês | WPRIM | ID: wpr-417027
ABSTRACT
Objective To evaluate perfusion computed tomography in the assessment of portal vein pressure changes in an experimental dog model of liver cirrhosis and portal hypertension.Methods The canine model of cirrhosis and portal hypertension was induced by portal vein stenosis with combination of systemic thioacetamide(TAA) feeding in drinking water.All of the Beagles in control group and cirrhotic group underwent hepatic perfusion on a spiral CT scanner.The parameters of hepatic perfusion were calculated by the method of deconvolution.The portal vein pressure was measured by a laparotomy surgery.Results ① In control group, the portal vein pressure was ( 14.5 ± 2.2) cm H2O, while it was (23.1 ± 2.8) cm H2O in PHT group, there was significant difference in the portal vein pressure between the two groups (P<0.05).② The blood flow(BF) was (112 ±14) ml·100 g-1·min-1 in controls, while ( 96 ± 11) ml·100 g-1·min-1 in PHT group; the blood volume ( BV ) in control group and PHT group was (10 ±3) ml·100 g-1 and (11 ± 5) ml· 100 g-1, respectively; the mean transit time( MTT) was (7.1 ± 2.0) s and (10.4 ± 3.5) s, respectively; the hepatic arterial fraction (HAF) was ( 24 ± 5) % and ( 37 ± 6)% , respectively; the hepatic arterial perfusion (HAP) was(27 ±6) ml·100 g-1·min-1 and (35 ±5) ml·100 g-1·min-1, respectively; the portal venous perfusion (PVP) was (85 ± 13) ml·100 g-1·min-1 and (61 ±11) ml·100 g-1·min-1, respectively.There was significant difference in all parameters between the two groups except the parameter BV(P < 0.05).③ In PHT group, the PVP and BF were negatively correlated with the portal vein pressure, while positively correlated with MTT and HAF.Portal vein pressure was negatively correlated with PVP, the equation, Y = 36.624 -0.219X, was deduced with linear regression analysis, by which the portal vein pressure in PHT Beagles was ( 23.2 ± 2.4) cm H2O, which was correlated with the observed by laparotomy value (23.1 ± 2.8) cm H2O (r = 0.843, P < 0.05).Conclusion CT perfusion is a new non-invasive and effective method for assessment of portal vein pressure.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of General Surgery Ano de publicação: 2011 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of General Surgery Ano de publicação: 2011 Tipo de documento: Artigo