Estimation of the effective doses for interventional employees in three common interventional diagnosis and treatment procedures / 中华放射医学与防护杂志
Chinese Journal of Radiological Medicine and Protection
; (12): 391-394, 2011.
Article
em Zh
| WPRIM
| ID: wpr-424153
Biblioteca responsável:
WPRO
ABSTRACT
Objective To study and estimate the effective dose of interventional employees in the common cerebralvascular, cardiovascular and liver interventional diagnosis and treatment.Methods The absorbed doses of tissue or organ of anthropomorphic phantom in these three procedures were estimated by the anthropomorphic phantom experiment.The effective doses were calculated by the tissue weight factor which was given by International Commission on Radiological Protection publication 103.Results The effective doses to high, medium and low group were 24.0, 9.7,6.8 μSv for cerebralvascular interventional diagnosis and treatment, and 36.3, 29.3, 17.8 μSv for cardiovascular interventional diagnosis and treatment, and 23.9, 11.3, 5.5 μ Sv for liver interventional diagnosis and treatment, respectively.Conclusions The effective doses of high, medium and low group of interventional employees in cardiovascular interventional procedure are higher than those of cerebralvascular and liver interventional procedures.
Texto completo:
1
Índice:
WPRIM
Tipo de estudo:
Diagnostic_studies
Idioma:
Zh
Revista:
Chinese Journal of Radiological Medicine and Protection
Ano de publicação:
2011
Tipo de documento:
Article