Dosimetric study of thoracic esophageal carcinoma radiotherapy using RapidArc combined with active breathing coordinator / 中华放射医学与防护杂志
Chinese Journal of Radiological Medicine and Protection ; (12): 364-368, 2012.
Artigo em Chinês | WPRIM | ID: wpr-427102
ABSTRACT
Objective To compare and analyze the dosimetric characteristics of the intensity-modulated arc therapy (RapidArc) combined with active breathing coordinator (ABC) in the thoracic esophageal carcinoma radiation therapy. Methods Ten thoracic esophageal carcinoma patients undergoing radiotherapy were selected for this study.The CT simulations were performed under three breath patterns respectivelymoderate deep inspiration breath-hold (mDIBH) with ABC aid; Set the trigger threshold to 80% of the peak of the respiration curve; and free breathing (FB).Based on the corresponding CT image sets,three treatment plans were generated for each patient respectivelyArc-ABC( three small arcs),ArcFB (consisted of two coplanar full arcs) and IMRT-FB plan.The following dosimetric parameters were compared among different plansD2%,D98%,V95,homogeneity index ( HI),conformal index ( CI ) the percentage of volume receiving dose of over x Gy (Vx),monitor unit (MU),control points and treatment time.Results The planning target volume ( PTV ) of FB was 376 cm3 which decreased to 260 cm3 after using ABC.For mDIBH and FB patients,the total lung volumes were 5964.6 cm3(35% more than FB) and 3838.8 cm3 respectively; the heart volumes were 524.4 cm3 and 642.7 cm3 respectively. No significant difference was observed among Arc-ABC,IMRT-FB and Arc-FB in terms of D2,D98,V95,CI and HI.For Arc-ABC plans,there were significant decreases of radiation dose in total-lung's V10,V20,V30,V40 and mean lung dose ( F =4.38,5.34,4.07,3.89,4.28,P <0.05).Various dose decreases of heart V20,V3,V40,Dmean and spinal cord Dmax were observed,yet no statistically significant difference existed.The MUs and total control points of Arc-ABC plans were significantly lower than other plans ( F =26.86,12.56,P < 0.05 ).Conclusions When thoracic esophageal carcinoma patients were treated with radiotherapy,the combined utilization of RapidArc and ABC can potentially decrease the volume of irradiated lung yet escalate the dose in target.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Radiological Medicine and Protection Ano de publicação: 2012 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Radiological Medicine and Protection Ano de publicação: 2012 Tipo de documento: Artigo