Your browser doesn't support javascript.
loading
Association of heart rate variability with 5-minute Apgar score in neonates with severe asphyxia / 临床儿科杂志
Journal of Clinical Pediatrics ; (12): 817-819, 2013.
Artigo em Chinês | WPRIM | ID: wpr-438718
ABSTRACT
Objective To explore the relationship between 5-minute Apgar score and heart rate variability (HRV) in severely asphyxiated neonates. Methods A total of 103 severely asphyxiated neonates with 1-minute Apgar score of 0 to 3 points were selected. They were divided into Group A (>7 points, n=50) and Group B (≤7 points, n=53) based on 5-minute Apgar score. Meanwhile, 40 full-term neonates with 1-and 5-minute Apgar score greater than 7 points were selected as control group. 24-hour dynamic electrocardiogram was performed and HRV was analyzed on the third day after birth in three groups. Results PNN50, rMSSD, SDSD were decreased and SDNN, SDANN were increased in group B as compared with group A and control group (P0.05). Conclusions Neonatal asphyxia can cause damage to autonomic nervous system. 5-minute Apgar score and HRV can be joint-ly used as a non-invasive index in autonomic nervous damage and its prognosis in asphyxiated newborns.

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Tipo de estudo: Estudo prognóstico Idioma: Chinês Revista: Journal of Clinical Pediatrics Ano de publicação: 2013 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Tipo de estudo: Estudo prognóstico Idioma: Chinês Revista: Journal of Clinical Pediatrics Ano de publicação: 2013 Tipo de documento: Artigo