Applied research on the ascites enrichment technology / 中国医学装备
China Medical Equipment
;
(12): 105-107, 2013.
Artigo
em Chinês
| WPRIM
| ID: wpr-439687
ABSTRACT
Objective:
To apply the development of ascites ultrafiltration treatment instrument and ascites ultrafiltration technology for clinical observation research.Methods:
By intraperitoneal on peritoneal ascites reinfusion of various causes of refractory ascites were treated.Results:
A total of 647 cases of patients with refractory ascites, with the average for 2.8±1.5 times, treatment time 2.4±1.2 hours/times; filtering out ascites in 8543±2427 ml/times, lost an average of 8.4±2.4 kg; abdominal circumference decreased from 108.7 before treatment to 87.4±15.3 cm; 24 hour urine volume increased significantly, from 257.8±235.6 ml to 725.8±436.9 ml (P<0.01). The incidence of adverse reaction was 3.3%(63/1892 cases).Conclusion:
Abdominal peritoneal ascites reinfusion method is simple, wide indications, adverse reactions, is a kind of method for the treatment of intractable ascites effectively.