Your browser doesn't support javascript.
loading
A Pulmonary Sequestered Segment with an Aberrant Pulmonary Arterial Supply: A Case of Unique Anomaly
Korean Journal of Radiology ; : 302-305, 2016.
Artigo em Inglês | WPRIM | ID: wpr-44144
ABSTRACT
We presented a rare case of a 64-year-old man with a combined anomaly of the bronchus and pulmonary artery that was detected incidentally. Computed tomography showed a hyperlucent, aerated sequestered segment of the right lower lung with an independent ectopic bronchus, which had no connection to the other airway. The affected segment was supplied by its own aberrant pulmonary artery branch from the right pulmonary trunk. This anomaly cannot be classified with any of the previously reported anomalies.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Artéria Pulmonar / Brônquios / Tomografia Computadorizada por Raios X / Sequestro Broncopulmonar / Pulmão Limite: Humanos / Masculino Idioma: Inglês Revista: Korean Journal of Radiology Ano de publicação: 2016 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Artéria Pulmonar / Brônquios / Tomografia Computadorizada por Raios X / Sequestro Broncopulmonar / Pulmão Limite: Humanos / Masculino Idioma: Inglês Revista: Korean Journal of Radiology Ano de publicação: 2016 Tipo de documento: Artigo