Your browser doesn't support javascript.
loading
Evaluation of Optical Quality Parameters and Ocular Aberrations in Multifocal Intraocular Lens Implanted Eyes
Yonsei Medical Journal ; : 1413-1420, 2014.
Artigo em Inglês | WPRIM | ID: wpr-44321
ABSTRACT

PURPOSE:

We investigated the correlations between optical quality parameters obtained from the double-pass system and ocular aberrations obtained from the ray-tracing aberrometer in multifocal intraocular lens (IOL) implanted eyes. MATERIALS AND

METHODS:

Twenty eyes from 20 patients were enrolled in this study. Modulation transfer function cutoff frequency, The Strehl ratio, objective scatter index, and objective pseudo-accommodation obtained from the double-pass system were compared with root mean square (RMS) total aberration, RMS higher-order aberration, and spherical aberration obtained from the ray-tracing aberrometer. Additionally, parameters of the double-pass system and ray-tracing aberrometer were compared with manifested refraction values and subjective visual acuity, respectively.

RESULTS:

There was no statistically significant correlation between optical quality parameters obtained from the double-pass system and ocular aberrations, except between the Strehl ratio and RMS total aberration (r=-0.566, p=0.018). No significant correlations were found between the parameters of both devices, and manifested refraction values or subjective visual acuity.

CONCLUSION:

Optical quality parameters, especially the Strehl ratio, in multifocal IOL implanted eyes were affected by RMS total aberration. Further studies based on accurate measurements of ocular aberrations and additional optical quality parameters are needed to delineate relationships between optical quality parameters and ocular aberrations in multifocal IOL implanted eyes.
Assuntos

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Refração Ocular / Extração de Catarata / Acuidade Visual / Implante de Lente Intraocular / Lentes Intraoculares Limite: Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Inglês Revista: Yonsei Medical Journal Ano de publicação: 2014 Tipo de documento: Artigo

Similares

MEDLINE

...
LILACS

LIS

Texto completo: DisponíveL Índice: WPRIM (Pacífico Ocidental) Assunto principal: Refração Ocular / Extração de Catarata / Acuidade Visual / Implante de Lente Intraocular / Lentes Intraoculares Limite: Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Inglês Revista: Yonsei Medical Journal Ano de publicação: 2014 Tipo de documento: Artigo