Evaluation of the effect of modified method of venous indwelling needle fixation / 中国实用护理杂志
Chinese Journal of Practical Nursing
;
(36): 34-35, 2014.
Artigo
em Chinês
| WPRIM
| ID: wpr-444229
ABSTRACT
Objective To investigate the modified fixation method in clinical use of intravenous indwelling needle.Methods 100 cases of patients with venous indwelling needle in our hospital emergency center were randomly divided into the observation group and the control group with 50 cases in each.The control group used conventional method of fixation,while the observation group was given modified method of fixation.The fixation effect of the 2 groups was compared.Results In the observation group,48 cases was with normal extubation,2 cases with abnomal extubation; while in the control group,35 cases was with normal extubation,15 cases with abnormal extubation.The comparison between the two groups showed statistically significant difference.Conclusions In the process of clinical use of intravenous indwelling needle,the modified fixation method is superior to conventional fixation method,which is worthy of clinical use.