Midazolam hypersensitivity during the transportation to theater: A case report / 대한마취과학회지
Korean Journal of Anesthesiology
;
: S1-S2, 2010.
Artigo
em Inglês
| WPRIM
| ID: wpr-44820
ABSTRACT
This report describes a rare case of perioperative midazolam hypersensitivity in a patient without any history of allergy. A 39-year-old man was admitted for endoscopic pansinus surgery. During transportation to the operating room after injecting antibiotic and midazolam intravenously, the patient complained of shortness of breath. At 3 months after the event, an intradermal sensitivity test for midazolam proved positive indicating the incident was caused by midazolam hypersensitivity.